Power Line Filter Modules
Explore Power Line Filter Modules components, specifications, manufacturers and sourcing options.
Browse Power Line Filter Modules parts and compare technical details, inventory references and datasheets to support your electronics project.
Submit part numbers or a BOM to request component pricing, availability and sourcing support.
| Photo | Mfr. Part # | Availability | Price | Quantity | Datasheet | Series | Packaging | Product Status | Filter Type | Configuration | Voltage - Rated DC | Voltage - Rated AC | Voltage - Rated AC (Phase to Ground/Neutral) | Voltage - Rated AC (Phase to Phase) | Current | Frequency - Operating | Applications | Approval Agency | Operating Temperature | Mounting Type | Termination Style | Inductance |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
B84143V0011R229LINE FILTER 11A CHASSIS MOUNT |
4,817 | - |
|
Datasheet | B84143V | Box | Active | Three Phase (Delta) | Single Stage | - | - | 300 V | 520 V | 11 A | 50/60Hz | General Purpose | cURus | -25°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
FN3287-100-35-C26-R65LINE FILTER 530/305VAC 100A CHAS |
1,546 | - |
|
Datasheet | FN 3287 | Box | Active | Three Phase (Delta) | Two Stage | - | 530V, 305V | 305 V | 530 V | 100 A | DC ~ 60Hz | Inverters, Power Drive Systems | - | -40°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
FN3287-100-35-C33-R65LINE FILTER 530/305VAC 100A CHAS |
4,282 | - |
|
Datasheet | FN 3287 | Box | Active | Three Phase (Delta) | Two Stage | - | 530V, 305V | 305 V | 530 V | 100 A | DC ~ 60Hz | Inverters, Power Drive Systems | - | -40°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
FN3288HV-80-34-C36-R65LINE FILTER 80A CHASSIS MOUNT |
2,738 | - |
|
Datasheet | FN 3288 | Box | Active | Three Phase (Delta) | Two Stage | - | - | 440 V | 760 V | 80 A | DC ~ 60Hz | Inverters, Power Drive Systems | - | -40°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
FN3288HVIT-80-34-C43-R60LINE FILTER 760VAC 80A CHASS MNT |
3,774 | - |
|
Datasheet | FN 3288 | Box | Active | Three Phase (Delta) | Two Stage | - | 760V | - | - | 80 A | DC ~ 60Hz | Inverters, Power Drive Systems | - | -40°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
FLLD3130AMHT6LINE FILTER 130A CHASSIS MOUNT |
1,023 | - |
|
Datasheet | * | Bulk | Last Time Buy | Three Phase (Delta) | Single Stage | - | - | 305 V | 530 V | 130 A | 50/60Hz | General Purpose | ENEC, UL | -25°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
|
B84143A0150R105LINE FILTER 520/300VAC 150A CHAS |
3,878 | - |
|
Datasheet | B84143A | Bulk | Active | Three Phase (Delta) | Single Stage | - | 520V, 300V | - | - | 150 A | 50/60Hz | General Purpose | cUR, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
STFE030-24LLINE FILTER 240VAC 3A DIN RAIL |
4,793 | - |
|
Datasheet | STFE | Bulk | Active | Single Phase | Single Stage | - | 240V | - | - | 3 A | 47Hz, 63Hz | General Purpose | CE, cURus | -40°C ~ 50°C | DIN Rail | Terminal Block | - |
|
FN3288-100-35-C26-R65LINE FILTER 530/305VAC 100A CHAS |
3,896 | - |
|
Datasheet | FN 3288 | Box | Active | Three Phase (Delta) | Two Stage | - | 530V, 305V | 305 V | 530 V | 100 A | DC ~ 60Hz | Inverters, Power Drive Systems | - | -40°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
TBC-50-683LINE FILTER 500VAC 50A CHASS MNT |
4,104 | - |
|
Datasheet | TBC | Box | Active | Three Phase (Wye) | Two Stage | - | 500V | - | - | 50 A | 50/60Hz | General Purpose | cURus, VDE | -40°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
|
FN3258H-75-34LINE FILTER 75A CHASSIS MOUNT |
2,176 | - |
|
Datasheet | FN 3258 | Tray | Active | Three Phase (Delta) | Single Stage | - | - | 300 V | 520 V | 75 A | DC ~ 60Hz | General Purpose | CSA, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
FN3288IT-100-35-C34-R60LINE FILTER 100A CHASSIS MOUNT |
2,248 | - |
|
Datasheet | FN 3288 | Box | Active | Three Phase (Delta) | Two Stage | - | - | - | - | 100 A | DC ~ 60Hz | Inverters, Power Drive Systems | - | -40°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
FN3100-50-34LINE FILTER 50A CHASSIS MOUNT |
3,712 | - |
|
Datasheet | FN 3100 | Tray | Active | Three Phase (Delta) | Single Stage | - | - | 300 V | 520 V | 50 A | DC ~ 60Hz | Regenerative Motor Drive | CSA, SEMKO, UR | -25°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
100KEHD10ABSDLINE FLTR 440VAC 100A CHASS MNT |
2,815 | - |
|
Datasheet | KEH-BS | Box | Active | Three Phase (Delta) | Two Stage | - | 440V | - | - | 100 A | 50/60Hz | General Purpose | CSA, UL | -25°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
STFE050-10NLINE FILTER 5A DIN RAIL |
3,829 | - |
|
Datasheet | - | Bulk | Active | Single Phase | Single Stage | - | - | - | - | 5 A | 47Hz, 63Hz | General Purpose | CE, cURus | -40°C ~ 50°C | DIN Rail | Terminal Block | - |
|
FMBC-0938-5010LLINE FILTER 480VAC 50A CHASS MNT |
1,939 | - |
|
Datasheet | FMBC | Bulk | Active | Three Phase (Delta) | Two Stage | - | 480V | - | - | 50 A | 50/60Hz | General Purpose | cURus, ENEC, VDE | -25°C ~ 100°C | Chassis Mount | Terminal Block | 1mH |
|
FMBC-A91F-7512LINE FILTER 480V/520VAC 75A CHAS |
1,836 | - |
|
Datasheet | FMBC NEO | Bulk | Active | Three Phase (Delta) | Two Stage | - | 480V, 520V | - | - | 75 A | 50/60Hz | General Purpose | cURus, ENEC, VDE | -25°C ~ 100°C | Chassis Mount | Terminal Block | L1 - 1.2mH, L2 - 13µH |
|
FMER-G62S-J517LINE FLTR 1200VDC 150A CHASS MNT |
4,252 | - |
|
Datasheet | FMER SOL | Bulk | Active | DC | Single Stage | 1200V (1.2kV) | - | - | - | 150 A | - | Photovoltaic Inverter | cURus | -40°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
FN3288-125-35-C17-R65LINE FILTER 530/305VAC 125A CHAS |
4,694 | - |
|
Datasheet | FN 3288 | Box | Active | Three Phase (Delta) | Two Stage | - | 530V, 305V | 305 V | 530 V | 125 A | DC ~ 60Hz | Inverters, Power Drive Systems | CE, ENEC, UR | -40°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
FN3288-125-35-C35-R65LINE FILTER 530/305VAC 125A CHAS |
4,963 | - |
|
Datasheet | FN 3288 | Tray | Active | Three Phase (Delta) | Two Stage | - | 530V, 305V | 305 V | 530 V | 125 A | DC ~ 60Hz | Inverters, Power Drive Systems | - | -40°C ~ 100°C | Chassis Mount | Terminal Block | - |
Power Line Filter Modules FAQs
Answers to common questions about component sourcing and electronic component sourcing.
Can HK CSY-ELECTRONICS help source Power Line Filter Modules components?
Submit part numbers, quantities and relevant requirements through our component RFQ form. Availability and quotation details are reviewed for each request.
Can I send a BOM for component sourcing?
Yes. Provide your bill of materials with required quantities and preferred manufacturers so our team can evaluate your sourcing request.
Do you also support PCB fabrication and assembly?
Yes. Our PCB and PCBA quotation form accepts board specifications and project files for fabrication and assembly inquiries.