| Photo | Mfr. Part # | Availability | Price | Quantity | Datasheet | Series | Packaging | Product Status | Filter Type | Configuration | Voltage - Rated DC | Voltage - Rated AC | Voltage - Rated AC (Phase to Ground/Neutral) | Voltage - Rated AC (Phase to Phase) | Current | Frequency - Operating | Applications | Approval Agency | Operating Temperature | Mounting Type | Termination Style | Inductance |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
FMAD-395B-3612LINE FILTER 300V/520VAC 36A CHAS |
4,001 | - |
|
Datasheet | FMAD | Box | Active | Three Phase (Wye) | Single Stage | - | 300V, 520V | - | - | 36 A | 50/60Hz | General Purpose | cURus, ENEC, VDE | -40°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
FMBC-345A-2514LINE FILTER 760VAC 25A CHASS MNT |
4,667 | - |
|
Datasheet | FMBC EP | Box | Active | Three Phase (Delta) | Two Stage | - | 760V | - | - | 25 A | 50/60Hz | General Purpose | cURus, ENEC, UL, VDE | -40°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
|
RTEN-5050LINE FILTER 500VAC/VDC 50A CHASS |
3,582 | - |
|
Datasheet | RTEN | Bulk | Active | Three Phase (Delta) | Single Stage | 500V | 500V | - | - | 50 A | - | General Purpose | EN, UL | -25°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
FMBD-345B-5012LINE FILTER 520VAC 50A CHASS MNT |
2,913 | - |
|
Datasheet | FMBD EP | Box | Active | Three Phase (Wye) | Two Stage | - | 520V | - | - | 50 A | 50/60Hz | General Purpose | cURus, ENEC, UL, VDE | -40°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
FMAD-395B-5012LINE FILTER 300V/520VAC 50A CHAS |
1,776 | - |
|
Datasheet | FMAD | Box | Active | Three Phase (Wye) | Single Stage | - | 300V, 520V | - | - | 50 A | 50/60Hz | General Purpose | cURus, ENEC, VDE | -40°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
FMBC-0994-1000LINE FILTER 480VAC 10A CHASS MNT |
3,879 | - |
|
Datasheet | FMBC ECO | Box | Active | Three Phase (Delta) | Two Stage | - | 480V | - | - | 10 A | 50/60Hz | Inverters, Power Drive Systems | cURus, ENEC, VDE | -25°C ~ 100°C | Chassis Mount | Terminal Block | 2.3mH |
|
FMAC-0A24-0813LINE FILTER 550VAC 8A CHASS MNT |
2,816 | - |
|
Datasheet | FMAC-Out | Bulk | Active | Three Phase (Delta) | Single Stage | - | 550V | - | - | 8 A | 50/60Hz | General Purpose | cURus, ENEC, VDE | -25°C ~ 100°C | Chassis Mount | Terminal Block | 200µH |
|
B84143A0065R106LINE FILTER 65A CHASSIS MOUNT |
4,345 | - |
|
Datasheet | B84143A | Box | Active | Three Phase (Delta) | Single Stage | - | - | - | - | 65 A | 50 ~ 60Hz | Converter | cUR, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
GTX-3300-Y000LINE FILTER 500VDC 30A CHASS MNT |
4,274 | - |
|
Datasheet | GTX | Bulk | Active | Three Phase (Delta) | Two Stage | 500V | - | - | - | 30 A | 50/60Hz | Inverters, Power Drive Systems | cUL, UL | -25°C ~ 55°C | Chassis Mount | Terminal Block | - |
|
3-138-352LINE FILTER 50A CHASSIS MOUNT |
1,068 | - |
|
Datasheet | FMBD EP | Box | Active | Three Phase (Wye) | Two Stage | - | - | 520 V | 760 V | 50 A | 50 ~ 60Hz | General Purpose | cURus, ENEC, VDE | -40°C ~ 100°C | Chassis Mount | Terminal Block, Threaded Post (M6) | - |
|
FMER-G62Q-5017LINE FLTR 1200VDC 50A CHASS MNT |
4,701 | - |
|
Datasheet | FMER SOL | Bulk | Active | DC | Single Stage | 1200V (1.2kV) | - | - | - | 50 A | - | Photovoltaic Inverter | cURus | -40°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
|
FMER-G92Q-5017LINE FLTR 1200VDC 50A CHASS MNT |
3,301 | - |
|
Datasheet | FMER SOL | Bulk | Active | DC | Single Stage | 1200V (1.2kV) | - | - | - | 50 A | - | Photovoltaic Inverter | cURus | -40°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
5500.2360LINE FILTER 125V/250VAC 16A CHAS |
3,337 | - |
|
Datasheet | FMAB CEE | Box | Active | Single Phase | Single Stage | - | 125V, 250V | - | - | 16 A | 50/60Hz | General Purpose | cURus, ENEC | -40°C ~ 85°C | Chassis Mount | Screw Clamp | - |
|
GTX-3400-Y000LINE FILTER 500VDC 40A CHASS MNT |
2,865 | - |
|
Datasheet | GTX | Bulk | Active | Three Phase (Delta) | Two Stage | 500V | - | - | - | 40 A | 50/60Hz | Inverters, Power Drive Systems | cUL, UL | -25°C ~ 55°C | Chassis Mount | Terminal Block | - |
|
|
B84243A8025W000LINE FILTER 530V/305VAC 25A CHAS |
1,401 | - |
|
Datasheet | B84243 | Box | Active | Three Phase (Delta) | Single Stage | - | 530V, 305V | - | - | 25 A | 50/60Hz | General Purpose | cUR, UR | -25°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
|
16BCF10LINE FILTER 16A CHASSIS MOUNT |
4,106 | - |
|
Datasheet | BCF | Box | Last Time Buy | Three Phase (Delta) | Two Stage | - | - | 277 V | 480 V | 16 A | 50/60Hz | Inverters, Power Drive Systems | UR, VDE | -10°C ~ 50°C | Chassis Mount | Terminal Block | - |
|
FMAD-T4QT-1660.EULINE FILTER 277V/480VAC 16A CHAS |
3,327 | - |
|
Datasheet | FMAD CEE | Box | Last Time Buy | Three Phase (Wye) | Single Stage | - | 277V, 480V | - | - | 16 A | 50/60Hz | General Purpose | cURus, ENEC | -40°C ~ 85°C | Chassis Mount | Screw Clamp | - |
|
GTX-3500-Y103LINE FILTER 500VDC 50A CHASS MNT |
3,314 | - |
|
Datasheet | GTX | Bulk | Active | Three Phase (Delta) | Two Stage | 500V | - | - | - | 50 A | 50/60Hz | Inverters, Power Drive Systems | cUL, UL | -25°C ~ 55°C | Chassis Mount | Terminal Block | - |
|
FMAC-0931-1610LINE FILTER 480V/520VAC 16A CHAS |
3,318 | - |
|
Datasheet | FMAC | Bulk | Active | Three Phase (Delta) | Single Stage | - | 480V, 520V | - | - | 16 A | 50/60Hz | Photovoltaic Inverter | cURus, ENEC, VDE | -25°C ~ 100°C | Chassis Mount | Terminal Block | 6mH |
|
FMER-G62Q-7517LINE FLTR 1200VDC 75A CHASS MNT |
1,607 | - |
|
Datasheet | FMER SOL | Bulk | Active | DC | Single Stage | 1200V (1.2kV) | - | - | - | 75 A | - | Photovoltaic Inverter | cURus | -40°C ~ 100°C | Chassis Mount | Terminal Block | - |
Power Line Filter Modules FAQs
Answers to common questions about component sourcing and electronic component sourcing.
Can HK CSY-ELECTRONICS help source Power Line Filter Modules components?
Submit part numbers, quantities and relevant requirements through our component RFQ form. Availability and quotation details are reviewed for each request.
Can I send a BOM for component sourcing?
Yes. Provide your bill of materials with required quantities and preferred manufacturers so our team can evaluate your sourcing request.
Do you also support PCB fabrication and assembly?
Yes. Our PCB and PCBA quotation form accepts board specifications and project files for fabrication and assembly inquiries.