| Photo | Mfr. Part # | Availability | Price | Quantity | Datasheet | Series | Packaging | Product Status | Filter Type | Configuration | Voltage - Rated DC | Voltage - Rated AC | Voltage - Rated AC (Phase to Ground/Neutral) | Voltage - Rated AC (Phase to Phase) | Current | Frequency - Operating | Applications | Approval Agency | Operating Temperature | Mounting Type | Termination Style | Inductance |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
6609044-6LINE FILTER 250VAC 20A CHASS MNT |
2,375 | - |
|
Datasheet | W | Bulk | Active | Single Phase | Two Stage | - | 250V | - | - | 20 A | 50/60Hz | General Purpose | CSA, UR, VDE | -10°C ~ 40°C | Chassis Mount | Quick Connect | 1.76mH |
|
16KEPS10ABSWLINE FILTER 440VAC 16A CHASS MNT |
1,522 | - |
|
Datasheet | KEP-BS | Bulk | Active | Three Phase (Wye) | Single Stage | - | 440V | - | - | 16 A | 50/60Hz | General Purpose | CSA, UL | -25°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
5500.2648.06LINE FILTER 125V/250VAC 60A CHAS |
4,158 | - |
|
Datasheet | FMAB NEO | Box | Active | Single Phase | Single Stage | - | 125V, 250V | - | - | 60 A | 50/60Hz | Medical | cURus, ENEC, VDE | -40°C ~ 100°C | Chassis Mount | Threaded Post (M6) | - |
|
FMBC-345B-6412LINE FILTER 520VAC 64A CHASS MNT |
1,834 | - |
|
Datasheet | FMBC EP | Box | Active | Three Phase (Delta) | Two Stage | - | 520V | - | - | 64 A | 50/60Hz | General Purpose | cURus, ENEC, UL, VDE | -40°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
6KEMS10BFPDHMLINE FILTER 520VAC 6A CHASS MNT |
4,059 | - |
|
Datasheet | KEM | Box | Active | Three Phase (Delta) | Single Stage | - | 520V | - | - | 6 A | 50 ~ 60Hz | Converter | CSA, UL | -25°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
FMBD-395A-2514LINE FILTER 760VAC 25A CHASS MNT |
4,210 | - |
|
Datasheet | FMBD EP | Box | Active | Three Phase (Wye) | Two Stage | - | 760V | - | - | 25 A | 50/60Hz | General Purpose | cURus, ENEC, UL, VDE | -40°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
7KEHD10BBSDLINE FILTER 520VAC 7A CHASS MNT |
4,382 | - |
|
Datasheet | KEH-BS | Box | Active | Three Phase (Delta) | Two Stage | - | 520V | - | - | 7 A | 50/60Hz | General Purpose | CSA, UL | -25°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
FMBC-345B-5012LINE FILTER 520VAC 50A CHASS MNT |
1,393 | - |
|
Datasheet | FMBC EP | Box | Active | Three Phase (Delta) | Two Stage | - | 520V | - | - | 50 A | 50/60Hz | General Purpose | cURus, ENEC, UL, VDE | -40°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
6KEMS10BFPDVMLINE FILTER 520VAC 6A CHASS MNT |
3,876 | - |
|
Datasheet | KEM | Box | Active | Three Phase (Delta) | Single Stage | - | 520V | - | - | 6 A | 50 ~ 60Hz | Converter | CSA, UL | -25°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
|
FN3270H-10-29LINE FILTER 480VAC 10A CHASS MNT |
4,070 | - |
|
Datasheet | FN 3270 | Tray | Not For New Designs | Three Phase (Delta) | Single Stage | - | 480V | 300 V | 520 V | 10 A | DC ~ 60Hz | Inverters, Power Drive Systems | CSA, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
|
FLLDU300A225I0LINE FILTER 440VDC 250VAC CHAS |
1,602 | - |
|
Datasheet | FLLDU | Bulk | Active | Single Phase | Single Stage | 440V | 250V | - | - | 300 A | 50/60Hz | General Purpose | - | -40°C ~ 85°C | Chassis Mount | Threaded Post (M12) | - |
|
|
10KEMS10AFPDLINE FILTER 440VAC 10A CHASS MNT |
1,716 | - |
|
Datasheet | KEM | Box | Active | Three Phase (Delta) | Single Stage | - | 440V | - | - | 10 A | 50/60Hz | Converter | CSA, UL | -25°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
6KEPS10BFPWHMLINE FILTER 520VAC 6A CHASS MNT |
1,749 | - |
|
Datasheet | KEP | Box | Active | Three Phase (Wye) | Single Stage | - | 520V | - | - | 6 A | 50 ~ 60Hz | Converter | CSA, UL | -25°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
16KEMS10ABSDLINE FILTER 440VAC 16A CHASS MNT |
1,859 | - |
|
Datasheet | KEM-BS | Bulk | Active | Three Phase (Delta) | Single Stage | - | 440V | - | - | 16 A | 50/60Hz | General Purpose | CSA, UL | -25°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
FTA-40-683LINE FILTER 500VAC 40A CHASS MNT |
4,456 | - |
|
Datasheet | FTA | Box | Active | Three Phase (Wye) | Single Stage | - | 500V | - | - | 40 A | 50/60Hz | General Purpose | cURus, VDE | -40°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
6KEPS10BFPWVMLINE FILTER 520VAC 6A CHASS MNT |
4,120 | - |
|
Datasheet | KEP | Box | Active | Three Phase (Wye) | Single Stage | - | 520V | - | - | 6 A | 50 ~ 60Hz | Converter | CSA, UL | -25°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
FN3287-10-44-C28-R65LINE FILTER 530V/305VAC 10A CHAS |
2,219 | - |
|
Datasheet | FN 3287 | Box | Active | Three Phase (Delta) | Two Stage | - | 530V, 305V | 305 V | 530 V | 10 A | DC ~ 60Hz | Inverters, Power Drive Systems | - | -40°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
FMAC-091C-1610LINE FILTER 480VAC 16A CHASS MNT |
4,003 | - |
|
Datasheet | FMAC ECO | Box | Active | Three Phase (Delta) | Single Stage | - | 480V | - | - | 16 A | 50/60Hz | Inverters, Power Drive Systems | cURus, ENEC, VDE | -25°C ~ 100°C | Chassis Mount | Terminal Block | 550µH |
|
|
10KEPS10AFPWLINE FILTER 440VAC 10A CHASS MNT |
4,821 | - |
|
Datasheet | KEP | Box | Active | Three Phase (Wye) | Single Stage | - | 440V | - | - | 10 A | 50/60Hz | Converter | CSA, UL | -25°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
10KEMS10AFPDHMLINE FILTER 440VAC 10A CHASS MNT |
1,959 | - |
|
Datasheet | KEM | Box | Active | Three Phase (Delta) | Single Stage | - | 440V | - | - | 10 A | 50 ~ 60Hz | Converter | CSA, UL | -25°C ~ 85°C | Chassis Mount | Terminal Block | - |
Power Line Filter Modules FAQs
Answers to common questions about component sourcing and electronic component sourcing.
Can HK CSY-ELECTRONICS help source Power Line Filter Modules components?
Submit part numbers, quantities and relevant requirements through our component RFQ form. Availability and quotation details are reviewed for each request.
Can I send a BOM for component sourcing?
Yes. Provide your bill of materials with required quantities and preferred manufacturers so our team can evaluate your sourcing request.
Do you also support PCB fabrication and assembly?
Yes. Our PCB and PCBA quotation form accepts board specifications and project files for fabrication and assembly inquiries.