| Photo | Mfr. Part # | Availability | Price | Quantity | Datasheet | Series | Packaging | Product Status | Filter Type | Configuration | Voltage - Rated DC | Voltage - Rated AC | Voltage - Rated AC (Phase to Ground/Neutral) | Voltage - Rated AC (Phase to Phase) | Current | Frequency - Operating | Applications | Approval Agency | Operating Temperature | Mounting Type | Termination Style | Inductance |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
STFE200-24LLINE FILTER 240VAC 20A DIN RAIL |
1,126 | - |
|
Datasheet | STFE | Bulk | Active | Single Phase | Single Stage | - | 240V | - | - | 20 A | 47Hz, 63Hz | General Purpose | CE, cURus | -40°C ~ 50°C | DIN Rail | Terminal Block | - |
|
|
FN2200-1500-99LINE FILTER 1200VDC 1.5KA CHASS |
1,958 | - |
|
Datasheet | FN 2200 | Box | Active | DC | Single Stage | 1200V (1.2kV) | - | - | - | 1.5 kA | - | Photovoltaic Inverter | cURus, ENEC | -40°C ~ 100°C | Chassis Mount | Terminal Post | - |
|
FN351H-180-36LINE FILTER 180A CHASSIS MOUNT |
3,715 | - |
|
Datasheet | FN 351 | Tray | Active | Three Phase (Delta) | Single Stage | - | - | 300 V | 520 V | 180 A | DC ~ 60Hz | Inverters, Power Drive Systems | - | -25°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
FN2210-2300-99-R5LINE FILTER 1000VDC 2.3KA CHASS |
2,246 | - |
|
Datasheet | FN 2210 | Box | Active | DC | Single Stage | 1000V (1kV) | - | - | - | 2.3 kA | DC | Inverters, Power Drive Systems | CE, cURus | -40°C ~ 100°C | Chassis Mount | Terminal Post | - |
|
FMAC-0955-H212ILINE FILTER 480/520VAC 180A CHAS |
2,854 | - |
|
Datasheet | FMAC | Bulk | Active | Three Phase (Delta) | Single Stage | - | 480V, 520V | - | - | 180 A | 50/60Hz | Photovoltaic Inverter | cURus, ENEC, VDE | -25°C ~ 100°C | Chassis Mount | Terminal Block | 400µH |
|
FMAD-0955-H210LINE FILTER 277/480VAC 180A CHAS |
3,701 | - |
|
Datasheet | FMAD | Bulk | Active | Three Phase (Wye) | Single Stage | - | 277V, 480V | - | - | 180 A | 50/60Hz | General Purpose | cURus, VDE | -25°C ~ 100°C | Chassis Mount | Terminal Block | 250µH |
|
FMAC-0956-H310LINE FILTER 480/520VAC 250A CHAS |
2,532 | - |
|
Datasheet | FMAC | Bulk | Active | Three Phase (Delta) | Single Stage | - | 480V, 520V | - | - | 250 A | 50/60Hz | Photovoltaic Inverter | cURus, ENEC, VDE | -25°C ~ 100°C | Chassis Mount | Terminal Block | 300µH |
|
FMAD-0956-H310LINE FILTER 277/480VAC 250A CHAS |
3,097 | - |
|
Datasheet | FMAD | Bag | Active | Three Phase (Wye) | Single Stage | - | 277V, 480V | - | - | 250 A | 50/60Hz | General Purpose | cURus, VDE | -25°C ~ 100°C | Chassis Mount | Terminal Block | 200µH |
|
FN2200B-2300-99LINE FILTER 1200VDC 2.3KA CHASS |
4,851 | - |
|
Datasheet | FN 2200 | Box | Active | DC | Single Stage | 1200V (1.2kV) | - | - | - | 2.3 kA | DC | Photovoltaic Inverter | cURus, ENEC, UKCA | -40°C ~ 100°C | Chassis Mount | Terminal Post | - |
|
FN3359-1000-99LINE FILTER 1KA CHASSIS MOUNT |
2,360 | - |
|
Datasheet | FN 3359 | Tray | Active | Three Phase (Delta) | Three Stage | - | - | 300 V | 520 V | 1 kA | DC ~ 60Hz | General Purpose | cURus, ENEC | -25°C ~ 100°C | Chassis Mount | Terminal Post | - |
|
FN3359HV-1600-99LINE FILTER 1.6KA CHASSIS MOUNT |
3,696 | - |
|
Datasheet | FN 3359 | Tray | Active | Three Phase (Delta) | Three Stage | - | - | 400 V | 690 V | 1.6 kA | DC ~ 60Hz | General Purpose | cURus, ENEC | -25°C ~ 100°C | Chassis Mount | Terminal Post | - |
|
5500.2640.01LINE FILTER 125V/250VAC 1A CHASS |
4,248 | - |
|
Datasheet | FMAB NEO | Box | Active | Single Phase | Single Stage | - | 125V, 250V | - | - | 1 A | 50/60Hz | General Purpose | cURus, ENEC, VDE | -40°C ~ 100°C | Chassis Mount | Quick Connect | - |
|
FN402B-1-02LINE FILTER 250VAC 1A TH |
1,484 | - |
|
Datasheet | FN 402 | Tray | Active | Single Phase | Single Stage | - | 250V | - | - | 1 A | DC ~ 400Hz | General Purpose | CSA, ENEC, UR | -25°C ~ 100°C | Through Hole | PC Pins | 10mH |
|
5500.2651.04LINE FILTER 125V/250VAC 3A CHASS |
3,819 | - |
|
Datasheet | FMAB NEO | Box | Active | Single Phase | Single Stage | - | 125V, 250V | - | - | 3 A | 50/60Hz | Medical | cURus, ENEC, VDE | -40°C ~ 100°C | Chassis Mount | Quick Connect | - |
|
5500.2641.01LINE FILTER 125V/250VAC 3A CHASS |
3,404 | - |
|
Datasheet | FMAB NEO | Box | Active | Single Phase | Single Stage | - | 125V, 250V | - | - | 3 A | 50/60Hz | General Purpose | cURus, ENEC, VDE | -40°C ~ 100°C | Chassis Mount | Quick Connect | - |
|
10IHE1LINE FLTR 120/250VAC 10A PANEL |
3,283 | - |
|
Datasheet | IH, Corcom | Bulk | Active | Single Phase | Single Stage | - | 120V, 250V | 4000 V | 1500 V | 10 A | 50Hz ~ 60Hz | Medical | CSA, UL, VDE | -10°C ~ 40°C | Panel Mount | Quick Connect | - |
|
5500.2079LINE FILTER 125V/250VAC 4A CHASS |
4,389 | - |
|
Datasheet | FMLB-41 | Bulk | Active | Single Phase | Single Stage | - | 125V, 250V | - | - | 4 A | 50/60Hz | Medical | cURus, ENEC, VDE | -25°C ~ 100°C | Chassis Mount | Quick Connect | 1.5mH |
|
5500.2100LINE FILTER 125V/250VAC 6A CHASS |
3,433 | - |
|
Datasheet | FMW-41 | Bulk | Active | Single Phase | Single Stage | - | 125V, 250V | - | - | 6 A | 50/60Hz | General Purpose | cURus, ENEC, VDE | -25°C ~ 100°C | Chassis Mount | Quick Connect | 800µH |
|
5500.2631.04LINE FILTER 125V/250VAC 3A CHASS |
2,094 | - |
|
Datasheet | FMAB NEO | Box | Active | Single Phase | Single Stage | - | 125V, 250V | - | - | 3 A | 50/60Hz | Medical | cURus, ENEC, VDE | -40°C ~ 100°C | Chassis Mount | Quick Connect | - |
|
10EK3LINE FILTER 250VAC 10A CHASS MNT |
3,576 | - |
|
Datasheet | K | Bulk | Active | Single Phase | Single Stage | - | 250V | - | - | 10 A | 50/60Hz | General Purpose | CSA, UR, VDE | -10°C ~ 40°C | Chassis Mount | Wire Leads | 495µH |
Power Line Filter Modules FAQs
Answers to common questions about component sourcing and electronic component sourcing.
Can HK CSY-ELECTRONICS help source Power Line Filter Modules components?
Submit part numbers, quantities and relevant requirements through our component RFQ form. Availability and quotation details are reviewed for each request.
Can I send a BOM for component sourcing?
Yes. Provide your bill of materials with required quantities and preferred manufacturers so our team can evaluate your sourcing request.
Do you also support PCB fabrication and assembly?
Yes. Our PCB and PCBA quotation form accepts board specifications and project files for fabrication and assembly inquiries.