Power Line Filter Modules
Explore Power Line Filter Modules components, specifications, manufacturers and sourcing options.
Browse Power Line Filter Modules parts and compare technical details, inventory references and datasheets to support your electronics project.
Submit part numbers or a BOM to request component pricing, availability and sourcing support.
| Photo | Mfr. Part # | Availability | Price | Quantity | Datasheet | Series | Packaging | Product Status | Filter Type | Configuration | Voltage - Rated DC | Voltage - Rated AC | Voltage - Rated AC (Phase to Ground/Neutral) | Voltage - Rated AC (Phase to Phase) | Current | Frequency - Operating | Applications | Approval Agency | Operating Temperature | Mounting Type | Termination Style | Inductance |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
FMBD-395B-3612LINE FILTER 520VAC 36A CHASS MNT |
1,305 | - |
|
Datasheet | FMBD EP | Box | Active | Three Phase (Wye) | Two Stage | - | 520V | - | - | 36 A | 50/60Hz | General Purpose | cURus, ENEC, UL, VDE | -40°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
FMBD-395B-5012LINE FILTER 520VAC 50A CHASS MNT |
3,087 | - |
|
Datasheet | FMBD EP | Box | Active | Three Phase (Wye) | Two Stage | - | 520V | - | - | 50 A | 50/60Hz | General Purpose | cURus, ENEC, UL, VDE | -40°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
3-138-349LINE FILTER 16A CHASSIS MOUNT |
1,718 | - |
|
Datasheet | FMBD EP | Box | Active | Three Phase (Wye) | Two Stage | - | - | 520 V | 760 V | 16 A | 50 ~ 60Hz | General Purpose | cURus, ENEC, VDE | -40°C ~ 100°C | Chassis Mount | Terminal Block, Threaded Post (M6) | - |
|
|
FN2412H-25-33LINE FILTER 520V/300VAC 25A DIN |
3,413 | - |
|
Datasheet | FN 2412 | Tray | Active | Single Phase | Single Stage | - | 520V, 300V | - | - | 25 A | DC ~ 400Hz | Regenerative Motor Drive | CSA, ENEC, UR | -25°C ~ 100°C | DIN Rail | Terminal Block | - |
|
FMAD-345B-5012LINE FILTER 300V/520VAC 50A CHAS |
1,900 | - |
|
Datasheet | FMAD | Box | Active | Three Phase (Wye) | Single Stage | - | 300V, 520V | - | - | 50 A | 50/60Hz | General Purpose | cURus, ENEC, VDE | -40°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
3-138-323LINE FILTER 36A CHASSIS MOUNT |
4,718 | - |
|
Datasheet | FMBC EP | Box | Active | Three Phase (Delta) | Two Stage | - | - | 520 V | 760 V | 36 A | 50 ~ 60Hz | General Purpose | cURus, ENEC, VDE | -40°C ~ 100°C | Chassis Mount | Terminal Block, Threaded Post (M6) | - |
|
|
FN3025HP-20-71LINE FILTER 20A CHASSIS MOUNT |
2,853 | - |
|
Datasheet | FN 3025 | Tray | Active | Three Phase (Delta) | Single Stage | - | - | 300 V | 520 V | 20 A | DC ~ 60Hz | General Purpose | CSA, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
FMAD-395B-6412LINE FILTER 300V/520VAC 64A CHAS |
2,551 | - |
|
Datasheet | FMAD | Box | Active | Three Phase (Wye) | Single Stage | - | 300V, 520V | - | - | 64 A | 50/60Hz | General Purpose | cURus, ENEC, VDE | -40°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
|
B84143A0035R106LINE FILTER 520V/300VAC 35A CHAS |
4,539 | - |
|
Datasheet | B84143A | Tray | Active | Three Phase (Delta) | Single Stage | - | 520V, 300V | - | - | 35 A | 50/60Hz | General Purpose | cUR, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
|
B84243A8017W000LINE FILTER 530V/305VAC 17A CHAS |
3,346 | - |
|
Datasheet | B84243 | Box | Active | Three Phase (Delta) | Single Stage | - | 530V, 305V | - | - | 17 A | 50/60Hz | General Purpose | cUR, UR | -25°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
FMBC-395B-6412LINE FILTER 520VAC 64A CHASS MNT |
1,459 | - |
|
Datasheet | FMBC EP | Box | Active | Three Phase (Delta) | Two Stage | - | 520V | - | - | 64 A | 50/60Hz | General Purpose | cURus, ENEC, UL, VDE | -40°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
|
FLLDU100A945I0LINE FLTR 350VDC 250VAC 100A CHA |
2,083 | - |
|
Datasheet | FLLDU | Bulk | Active | Single Phase | Single Stage | 350V | 250V | - | - | 100 A | 50/60Hz | General Purpose | UR | -40°C ~ 85°C | Chassis Mount | Threaded Post (M8) | - |
|
FN3288-10-44-C34-R65LINE FILTER 530V/305VAC 10A CHAS |
4,503 | - |
|
Datasheet | FN 3288 | Box | Active | Three Phase (Delta) | Two Stage | - | 530V, 305V | 305 V | 530 V | 10 A | DC ~ 60Hz | Inverters, Power Drive Systems | - | -40°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
|
TAH-20-683LINE FILTER 500VAC 20A CHASS MNT |
2,030 | - |
|
Datasheet | TAH | Box | Active | Three Phase (Delta) | Single Stage | - | 500V | - | - | 20 A | 50/60Hz | General Purpose | cURus, VDE | -40°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
5500.2066LINE FILTER 125V/250VAC 30A CHAS |
2,387 | - |
|
Datasheet | FMAB | Bulk | Active | Single Phase | Single Stage | - | 125V, 250V | - | - | 30 A | 50/60Hz | General Purpose | cURus, ENEC, VDE | -25°C ~ 100°C | Chassis Mount | Terminal Block | 1.5mH |
|
FN3288IT-10-44-C34-R60LINE FILTER 10A CHASSIS MOUNT |
4,252 | - |
|
Datasheet | FN 3288 | Box | Active | Three Phase (Delta) | Two Stage | - | - | - | - | 10 A | DC ~ 60Hz | Inverters, Power Drive Systems | - | -40°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
|
FLLDU040A026I0LINE FLTR 750VDC 440VAC 40A CHAS |
4,306 | - |
|
Datasheet | FLLDU | Bulk | Active | Single Phase | Single Stage | 750V | 440V | - | - | 40 A | 50/60Hz | General Purpose | UR | -40°C ~ 85°C | Chassis Mount | Threaded Post (M6) | - |
|
|
B84143A0050R106LINE FILTER 520V/300VAC 50A CHAS |
3,349 | - |
|
Datasheet | B84143A | Tray | Active | Three Phase (Delta) | Single Stage | - | 520V, 300V | - | - | 50 A | 50/60Hz | General Purpose | cUR, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
FN3288-16-44-C26-R65LINE FILTER 530V/305VAC 16A CHAS |
3,541 | - |
|
Datasheet | FN 3288 | Box | Active | Three Phase (Delta) | Two Stage | - | 530V, 305V | 305 V | 530 V | 16 A | DC ~ 60Hz | Inverters, Power Drive Systems | - | -40°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
FN3287-20-33-C21-R65LINE FILTER 530V/305VAC 20A CHAS |
1,351 | - |
|
Datasheet | FN 3287 | Bulk | Active | Three Phase (Delta) | Two Stage | - | 530V, 305V | 305 V | 530 V | 20 A | DC ~ 60Hz | Inverters, Power Drive Systems | CE, ENEC, UR | -40°C ~ 100°C | Chassis Mount | Terminal Block | - |
Power Line Filter Modules FAQs
Answers to common questions about component sourcing and electronic component sourcing.
Can HK CSY-ELECTRONICS help source Power Line Filter Modules components?
Submit part numbers, quantities and relevant requirements through our component RFQ form. Availability and quotation details are reviewed for each request.
Can I send a BOM for component sourcing?
Yes. Provide your bill of materials with required quantities and preferred manufacturers so our team can evaluate your sourcing request.
Do you also support PCB fabrication and assembly?
Yes. Our PCB and PCBA quotation form accepts board specifications and project files for fabrication and assembly inquiries.