Power Line Filter Modules
Explore Power Line Filter Modules components, specifications, manufacturers and sourcing options.
Browse Power Line Filter Modules parts and compare technical details, inventory references and datasheets to support your electronics project.
Submit part numbers or a BOM to request component pricing, availability and sourcing support.
| Photo | Mfr. Part # | Availability | Price | Quantity | Datasheet | Series | Packaging | Product Status | Filter Type | Configuration | Voltage - Rated DC | Voltage - Rated AC | Voltage - Rated AC (Phase to Ground/Neutral) | Voltage - Rated AC (Phase to Phase) | Current | Frequency - Operating | Applications | Approval Agency | Operating Temperature | Mounting Type | Termination Style | Inductance |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
FN5040-115-87LINE FILTER 115A CHASSIS MOUNT |
4,978 | - |
|
Datasheet | FN 5040 | Box | Obsolete | Three Phase (Delta) | Single Stage | - | - | - | - | 115 A | - | Regenerative Motor Drive | cURus | -25°C ~ 70°C | Chassis Mount | Terminal Block | 500µH |
|
FN5040-180-99LINE FILTER 180A CHASSIS MOUNT |
4,097 | - |
|
Datasheet | FN 5040 | Box | Obsolete | Three Phase (Delta) | Single Stage | - | - | - | - | 180 A | - | Regenerative Motor Drive | cURus | -25°C ~ 70°C | Chassis Mount | Terminal Block | 300µH |
|
FN5040-260-99LINE FILTER 260A CHASSIS MOUNT |
4,550 | - |
|
Datasheet | FN 5040 | Box | Obsolete | Three Phase (Delta) | Single Stage | - | - | - | - | 260 A | - | Regenerative Motor Drive | cURus | -25°C ~ 70°C | Chassis Mount | Terminal Block | 200µH |
|
FN5040-410-99LINE FILTER 410A CHASSIS MOUNT |
1,460 | - |
|
Datasheet | FN 5040 | Box | Obsolete | Three Phase (Delta) | Single Stage | - | - | - | - | 410 A | - | Regenerative Motor Drive | cURus | -25°C ~ 70°C | Chassis Mount | Terminal Block | 130µH |
|
FN5040-480-99LINE FILTER 480A CHASSIS MOUNT |
4,650 | - |
|
Datasheet | FN 5040 | Box | Obsolete | Three Phase (Delta) | Single Stage | - | - | - | - | 480 A | - | Regenerative Motor Drive | cURus | -25°C ~ 70°C | Chassis Mount | Terminal Block | 110µH |
|
FN5040-660-99LINE FILTER 660A CHASSIS MOUNT |
1,872 | - |
|
Datasheet | FN 5040 | Box | Obsolete | Three Phase (Delta) | Single Stage | - | - | - | - | 660 A | - | Regenerative Motor Drive | cURus | -25°C ~ 70°C | Chassis Mount | Terminal Block | 140µH |
|
FN5040-750-99LINE FILTER 750A CHASSIS MOUNT |
2,410 | - |
|
Datasheet | FN 5040 | Box | Obsolete | Three Phase (Delta) | Single Stage | - | - | - | - | 750 A | - | Regenerative Motor Drive | cURus | -25°C ~ 70°C | Chassis Mount | Terminal Block | 120µH |
|
FN5040-880-99LINE FILTER 880A CHASSIS MOUNT |
1,434 | - |
|
Datasheet | FN 5040 | Box | Obsolete | Three Phase (Delta) | Single Stage | - | - | - | - | 880 A | - | Regenerative Motor Drive | cURus | -25°C ~ 70°C | Chassis Mount | Terminal Block | 110µH |
|
FN5040-1200-99LINE FILTER 1.2KA CHASSIS MOUNT |
2,939 | - |
|
Datasheet | FN 5040 | Box | Obsolete | Three Phase (Delta) | Single Stage | - | - | - | - | 1.2 kA | - | Regenerative Motor Drive | cURus | -25°C ~ 70°C | Chassis Mount | Terminal Block | 75µH |
|
FN5045-10-44LINE FILTER 10A CHASSIS MOUNT |
1,394 | - |
|
Datasheet | FN 5045 | Box | Obsolete | Three Phase (Delta) | Single Stage | - | - | - | - | 10 A | - | Regenerative Motor Drive | cURus | -25°C ~ 70°C | Chassis Mount | Terminal Block | 5.2mH |
|
FN5045-17-33LINE FILTER 17A CHASSIS MOUNT |
1,152 | - |
|
Datasheet | FN 5045 | Box | Obsolete | Three Phase (Delta) | Single Stage | - | - | - | - | 17 A | - | Regenerative Motor Drive | cURus | -25°C ~ 70°C | Chassis Mount | Terminal Block | 3.1mH |
|
FN5045-24-33LINE FILTER 24A CHASSIS MOUNT |
4,580 | - |
|
Datasheet | FN 5045 | Box | Obsolete | Three Phase (Delta) | Single Stage | - | - | - | - | 24 A | - | Regenerative Motor Drive | cURus | -25°C ~ 70°C | Chassis Mount | Terminal Block | 2.4mH |
|
FN5045-38-33LINE FILTER 38A CHASSIS MOUNT |
2,444 | - |
|
Datasheet | FN 5045 | Box | Obsolete | Three Phase (Delta) | Single Stage | - | - | - | - | 38 A | - | Regenerative Motor Drive | cURus | -25°C ~ 70°C | Chassis Mount | Terminal Block | 1.6mH |
|
FN5045-48-34LINE FILTER 48A CHASSIS MOUNT |
1,479 | - |
|
Datasheet | FN 5045 | Box | Obsolete | Three Phase (Delta) | Single Stage | - | - | - | - | 48 A | - | Regenerative Motor Drive | cURus | -25°C ~ 70°C | Chassis Mount | Terminal Block | 1.1mH |
|
FN5045-75-35LINE FILTER 75A CHASSIS MOUNT |
3,066 | - |
|
Datasheet | FN 5045 | Box | Obsolete | Three Phase (Delta) | Single Stage | - | - | - | - | 75 A | - | Regenerative Motor Drive | cURus | -25°C ~ 70°C | Chassis Mount | Terminal Block | 750µH |
|
FN5045-115-35LINE FILTER 115A CHASSIS MOUNT |
1,894 | - |
|
Datasheet | FN 5045 | Box | Obsolete | Three Phase (Delta) | Single Stage | - | - | - | - | 115 A | - | Regenerative Motor Drive | cURus | -25°C ~ 70°C | Chassis Mount | Terminal Block | 500µH |
|
FN5045-180-99LINE FILTER 180A CHASSIS MOUNT |
3,273 | - |
|
Datasheet | FN 5045 | Box | Obsolete | Three Phase (Delta) | Single Stage | - | - | - | - | 180 A | - | Regenerative Motor Drive | cURus | -25°C ~ 70°C | Chassis Mount | Terminal Block | 300µH |
|
FN5045-260-99LINE FILTER 260A CHASSIS MOUNT |
1,683 | - |
|
Datasheet | FN 5045 | Box | Obsolete | Three Phase (Delta) | Single Stage | - | - | - | - | 260 A | - | Regenerative Motor Drive | cURus | -25°C ~ 70°C | Chassis Mount | Terminal Block | 200µH |
|
FN5045-410-99LINE FILTER 410A CHASSIS MOUNT |
1,597 | - |
|
Datasheet | FN 5045 | Box | Obsolete | Three Phase (Delta) | Single Stage | - | - | - | - | 410 A | - | Regenerative Motor Drive | cURus | -25°C ~ 70°C | Chassis Mount | Terminal Block | 130µH |
|
FN5045-480-99LINE FILTER 480A CHASSIS MOUNT |
1,936 | - |
|
Datasheet | FN 5045 | Box | Obsolete | Three Phase (Delta) | Single Stage | - | - | - | - | 480 A | - | Regenerative Motor Drive | cURus | -25°C ~ 70°C | Chassis Mount | Terminal Block | 110µH |
Power Line Filter Modules FAQs
Answers to common questions about component sourcing and electronic component sourcing.
Can HK CSY-ELECTRONICS help source Power Line Filter Modules components?
Submit part numbers, quantities and relevant requirements through our component RFQ form. Availability and quotation details are reviewed for each request.
Can I send a BOM for component sourcing?
Yes. Provide your bill of materials with required quantities and preferred manufacturers so our team can evaluate your sourcing request.
Do you also support PCB fabrication and assembly?
Yes. Our PCB and PCBA quotation form accepts board specifications and project files for fabrication and assembly inquiries.