Power Line Filter Modules
Explore Power Line Filter Modules components, specifications, manufacturers and sourcing options.
Browse Power Line Filter Modules parts and compare technical details, inventory references and datasheets to support your electronics project.
Submit part numbers or a BOM to request component pricing, availability and sourcing support.
| Photo | Mfr. Part # | Availability | Price | Quantity | Datasheet | Series | Packaging | Product Status | Filter Type | Configuration | Voltage - Rated DC | Voltage - Rated AC | Voltage - Rated AC (Phase to Ground/Neutral) | Voltage - Rated AC (Phase to Phase) | Current | Frequency - Operating | Applications | Approval Agency | Operating Temperature | Mounting Type | Termination Style | Inductance |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
FN5045-62-34LINE FILTER 62A CHASSIS MOUNT |
4,957 | - |
|
Datasheet | FN 5045 | Box | Obsolete | Three Phase (Delta) | Single Stage | - | - | - | - | 62 A | - | Regenerative Motor Drive | cURus | -25°C ~ 70°C | Chassis Mount | Terminal Block | 850µH |
|
RTEN-2200LINE FILTER 200A CHASSIS MOUNT |
3,048 | - |
|
Datasheet | RTEN-2 | Bulk | Active | Three Phase (Delta) | Single Stage | - | - | 250 V | 250 V | 200 A | - | General Purpose | ENEC, UL | -25°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
|
FMER-G92V-S057LINE FLTR 1200VDC 1KA CHASS MNT |
4,429 | - |
|
Datasheet | FMER SOL | Bulk | Active | DC | Single Stage | 1200V (1.2kV) | - | - | - | 1 kA | - | Photovoltaic Inverter | cURus | -40°C ~ 100°C | Chassis Mount | Terminal Post | - |
|
DG200-5FFLINE FILTER, 3-PHASE, 600VAC, 20 |
4,002 | - |
|
Datasheet | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
FLLD31K0APZI1LINE FILTER 1KA CHASSIS MOUNT |
1,721 | - |
|
Datasheet | FLLD3 – PH | Bulk | Last Time Buy | Three Phase (Delta) | Two Stage | - | - | 400 V | 690 V | 1 kA | 50 ~ 60Hz | General Purpose | UL | -40°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
FN3280H-600-99LINE FILTER 600A CHASSIS MOUNT |
3,603 | - |
|
Datasheet | FN 3280 | Bulk | Active | Three Phase (Wye) | Two Stage | - | - | 300 V | 520 V | 600 A | DC ~ 60Hz | General Purpose | CE, CSA, ENEC, UKCA, UR | -25°C ~ 100°C | Chassis Mount | Terminal Post | - |
|
B84143C0400S250LINE FILTER 400A CHASSIS MOUNT |
3,850 | - |
|
Datasheet | B84143C*S250 | Box | Active | Three Phase (Delta) | Two Stage | - | - | 305 V | 530 V | 400 A | 50 ~ 60Hz | Converter | cUR, ENEC, UR | - | Chassis Mount | Terminal Post | - |
|
FN3359HV-320-99LINE FILTER 320A CHASSIS MOUNT |
3,443 | - |
|
Datasheet | FN 3359 | Tray | Active | Three Phase (Delta) | Three Stage | - | - | 400 V | 690 V | 320 A | DC ~ 60Hz | General Purpose | cURus, ENEC | -25°C ~ 100°C | Chassis Mount | Terminal Post | - |
|
B84143K0600S081LINE FILTER 760/440VAC 600A CHAS |
4,664 | - |
|
Datasheet | B84143K | Box | Active | Three Phase (Delta) | Two Stage | - | 760V, 440V | 760 V | 440 V | 600 A | 50/60Hz | General Purpose | cUR, UR | -25°C ~ 100°C | Chassis Mount | Terminal Post | - |
|
RTEN-2250LINE FILTER 250A CHASSIS MOUNT |
3,992 | - |
|
Datasheet | RTEN-2 | Bulk | Active | Three Phase (Delta) | Single Stage | - | - | 250 V | 250 V | 250 A | - | General Purpose | ENEC, UL | -25°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
B84143C0315S251LINE FILTER 315A CHASSIS MOUNT |
4,968 | - |
|
Datasheet | B84143C*S251 | Box | Active | Three Phase (Delta) | Two Stage | - | - | 440 V | 760 V | 315 A | 50 ~ 60Hz | Converter | cUR, ENEC, UR | - | Chassis Mount | Terminal Post | - |
|
B84143B0600S021LINE FILTER 760/440VAC 600A CHAS |
3,866 | - |
|
Datasheet | B84143B | Bulk | Active | Three Phase (Delta) | Two Stage | - | 760V, 440V | - | - | 600 A | 50 ~ 60Hz | Inverters, Power Drive Systems | cUL, UL | - | Chassis Mount | Terminal Post, Threaded Post (M10) | - |
|
|
500TDSS84LINE FLTR 480VAC 500A CHASS MNT |
3,427 | - |
|
Datasheet | TDS | Box | Active | Three Phase (Delta) | Single Stage | - | 480V | - | - | 500 A | 50/60Hz | General Purpose | - | - | Chassis Mount | Quick Connect | 3µH |
|
B84142C1600S081LINE FILTER 1500VDC 1.6KA CHASS |
4,537 | - |
|
Datasheet | B84142C | Bulk | Active | DC | Two Stage | 1500V (1.5kV) | - | - | - | 1.6 kA | 50 ~ 60Hz | Converter | cUL, cUR, UL,UR | -25°C ~ 100°C | Chassis Mount | Terminal Post | - |
|
|
1000APS12PLINE FILTER 690VAC 1KA CHASS MNT |
3,406 | - |
|
Datasheet | APS | Box | Active | Three Phase (Delta) | Three Stage | - | 690V | - | - | 1 kA | 50/60Hz | General Purpose | - | -10°C ~ 50°C | Chassis Mount | Terminal Post | - |
|
RTEN-2300LINE FILTER 300A CHASSIS MOUNT |
2,416 | - |
|
Datasheet | RTEN-2 | Bulk | Active | Three Phase (Delta) | Single Stage | - | - | 250 V | 250 V | 300 A | - | General Purpose | ENEC, UL | -25°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
B84142J1600S081LINE FLTR 1KVDC 600VAC 1.6KA CHA |
4,866 | - |
|
Datasheet | B84142 | Box | Active | DC | Two Stage | 1000V (1kV) | 600V | - | - | 1.6 kA | - | Photovoltaic Inverter | cUR, UR | -25°C ~ 100°C | Chassis Mount | Terminal Post | - |
|
FMCC-I93E-Q054LINE FILTER 800A CHASSIS MOUNT |
4,082 | - |
|
Datasheet | FMCC SOL | Box | Active | Three Phase (Delta) | Three Stage | - | - | 520 V | 760 V | 800 A | 50 ~ 60Hz | General Purpose | cURus | -40°C ~ 100°C | Chassis Mount | Terminal Post, Threaded Post (M12) | - |
|
FN3311-1500-99-C28-R55LINE FILTER 1.5KA CHASSIS MOUNT |
4,810 | - |
|
Datasheet | FN 3311 | Bulk | Active | Three Phase (Delta) | Single Stage | - | - | 300 V | 520 V | 1.5 kA | DC ~ 60Hz | General Purpose | CE, cURus, ENEC, UKCA | -40°C ~ 100°C | Chassis Mount | Terminal Post | - |
|
B84144B0600S120LINE FILTER 600A CHASSIS MOUNT |
2,805 | - |
|
Datasheet | B84144 | Bulk | Active | Three Phase (Wye) | Three Stage | - | - | 530 V | 305 V | 600 A | 50 ~ 60Hz | Converter | cUR, UR | -25°C ~ 100°C | Chassis Mount | Terminal Post | - |
Power Line Filter Modules FAQs
Answers to common questions about component sourcing and electronic component sourcing.
Can HK CSY-ELECTRONICS help source Power Line Filter Modules components?
Submit part numbers, quantities and relevant requirements through our component RFQ form. Availability and quotation details are reviewed for each request.
Can I send a BOM for component sourcing?
Yes. Provide your bill of materials with required quantities and preferred manufacturers so our team can evaluate your sourcing request.
Do you also support PCB fabrication and assembly?
Yes. Our PCB and PCBA quotation form accepts board specifications and project files for fabrication and assembly inquiries.