PRODUCT CATEGORIES

Power Line Filter Modules

Explore Power Line Filter Modules components, specifications, manufacturers and sourcing options.

Browse Power Line Filter Modules parts and compare technical details, inventory references and datasheets to support your electronics project.

Submit part numbers or a BOM to request component pricing, availability and sourcing support.

Photo Mfr. Part # Availability Price Quantity Datasheet Series Packaging Product Status Filter Type Configuration Voltage - Rated DC Voltage - Rated AC Voltage - Rated AC (Phase to Ground/Neutral) Voltage - Rated AC (Phase to Phase) Current Frequency - Operating Applications Approval Agency Operating Temperature Mounting Type Termination Style Inductance
B84142C1000S081 EPCOS - TDK Electronics

B84142C1000S081

LINE FLTR 1500VDC 1KA CHASS MNT

EPCOS - TDK Electronics

1,945 -
Datasheet B84142C Bulk Active Single Phase Two Stage 1500V (1.5kV) - - - 1 kA 50 ~ 60Hz Converter cUL, cUR, UL,UR -25°C ~ 100°C Chassis Mount Terminal Post -
B84144B0250S121 EPCOS - TDK Electronics

B84144B0250S121

LINE FILTER 250A CHASSIS MOUNT

EPCOS - TDK Electronics

4,355 -
Datasheet B84144 Bulk Active Three Phase (Wye) Three Stage - - 530 V 305 V 250 A 50 ~ 60Hz Converter cUR, UR -25°C ~ 100°C Chassis Mount Terminal Post -
FN5420-18-33-E2FXT Schaffner EMC Inc.

FN5420-18-33-E2FXT

LINE FILTER 18A CHASSIS MOUNT

Schaffner EMC Inc.

2,939 -
Datasheet FN 5420 Bulk Active Three Phase (Delta) Single Stage - - 480 V 530 V 18 A DC ~ 60Hz Regenerative Motor Drive CE, cURus, UKCA -40°C ~ 70°C Chassis Mount Terminal Block 2.45mH
400TDSS84 Delta Electronics

400TDSS84

LINE FLTR 480VAC 400A CHASS MNT

Delta Electronics

4,633 -
Datasheet TDS Box Active Three Phase (Delta) Single Stage - 480V - - 400 A 50/60Hz General Purpose - - Chassis Mount Quick Connect 3µH
B84142J1000S081 EPCOS - TDK Electronics

B84142J1000S081

LINE FLTR 1000VDC 600VAC 1KA CHA

EPCOS - TDK Electronics

1,348 -
Datasheet B84142 Box Active DC Two Stage 1000V (1kV) 600V - - 1 kA - Photovoltaic Inverter cUR, UR -25°C ~ 100°C Chassis Mount Terminal Post -
SF1883 Tri-Mag, LLC

SF1883

LINE FILTER ASSY

Tri-Mag, LLC

3,841 -
Datasheet - Bulk Active - - - - - - - - - - - - - -
RTCN-5300 TDK-Lambda

RTCN-5300

LINE FILTER 500VAC/VDC 300A CHAS

TDK-Lambda

2,162 -
Datasheet RTCN Bulk Active Three Phase (Delta) Single Stage 500V 500V - - 300 A - General Purpose EN -25°C ~ 85°C Chassis Mount Terminal Block -
RTHC-5100 TDK-Lambda

RTHC-5100

LINE FILTER 500VAC/VDC 100A CHAS

TDK-Lambda

2,286 -
Datasheet RTHC Bulk Active Three Phase (Delta) Two Stage 500V 500V - - 100 A - General Purpose EN, UL -25°C ~ 85°C Chassis Mount Terminal Block -
2-6609974-1 TE Connectivity Corcom Filters

2-6609974-1

LINE FILTER 180A CHASSIS MOUNT

TE Connectivity Corcom Filters

3,947 -
Datasheet FCD Bag Last Time Buy Three Phase (Delta) Single Stage - - 277 V 480 V 180 A 50/60Hz Regenerative Motor Drive UR -10°C ~ 40°C Chassis Mount Terminal Block -
FN3359HV-180-28 Schaffner EMC Inc.

FN3359HV-180-28

LINE FILTER 180A CHASSIS MOUNT

Schaffner EMC Inc.

3,875 -
Datasheet FN 3359 Tray Active Three Phase (Delta) Three Stage - - 400 V 690 V 180 A DC ~ 60Hz General Purpose cURus, ENEC -25°C ~ 100°C Chassis Mount Threaded Post (M10) -
FN3100-200-40 Schaffner EMC Inc.

FN3100-200-40

LINE FILTER 200A CHASSIS MOUNT

Schaffner EMC Inc.

2,536 -
Datasheet FN 3100 Tray Active Three Phase (Delta) Single Stage - - 300 V 520 V 200 A DC ~ 60Hz Regenerative Motor Drive CSA, SEMKO, UR -25°C ~ 100°C Chassis Mount Terminal Block -
FTA-150-104-H Cosel USA, Inc.

FTA-150-104-H

LINE FLTR 500VAC 150A CHASS MNT

Cosel USA, Inc.

4,055 -
Datasheet FTA Box Active Three Phase (Wye) Single Stage - 500V - - 150 A 50/60Hz General Purpose cURus, VDE -40°C ~ 85°C Chassis Mount Terminal Block -
FTA-150-155-H Cosel USA, Inc.

FTA-150-155-H

LINE FLTR 500VAC 150A CHASS MNT

Cosel USA, Inc.

3,668 -
Datasheet FTA Box Active Three Phase (Wye) Single Stage - 500V - - 150 A 50/60Hz General Purpose cURus, VDE -40°C ~ 85°C Chassis Mount Terminal Block -
FTA-150-223-H Cosel USA, Inc.

FTA-150-223-H

LINE FLTR 500VAC 150A CHASS MNT

Cosel USA, Inc.

1,174 -
Datasheet FTA Box Active Three Phase (Wye) Single Stage - 500V - - 150 A 50/60Hz General Purpose cURus, VDE -40°C ~ 85°C Chassis Mount Terminal Block -
FTA-150-683-H Cosel USA, Inc.

FTA-150-683-H

LINE FLTR 500VAC 150A CHASS MNT

Cosel USA, Inc.

1,867 -
Datasheet FTA Box Active Three Phase (Wye) Single Stage - 500V - - 150 A 50/60Hz General Purpose cURus, VDE -40°C ~ 85°C Chassis Mount Terminal Block -
SF1990 Tri-Mag, LLC

SF1990

LINE FILTER ASSY

Tri-Mag, LLC

4,814 -
Datasheet - Bulk Active - - - - - - - - - - - - - -
FN5020-25-33 Schaffner EMC Inc.

FN5020-25-33

LINE FILTER 25A CHASSIS MOUNT

Schaffner EMC Inc.

1,467 -
Datasheet FN 5020 Tray Obsolete Three Phase (Delta) Single Stage - - 288 V 500 V 25 A - Regenerative Motor Drive - -25°C ~ 100°C Chassis Mount Terminal Block, Wire Leads -
RTHN-2080 TDK-Lambda

RTHN-2080

LINE FILTER 80A CHASSIS MOUNT

TDK-Lambda

3,897 -
Datasheet RTHN-2 Bulk Active Three Phase (Delta) Two Stage - - 250 V 250 V 80 A - General Purpose ENEC, UL -25°C ~ 85°C Chassis Mount Terminal Block -
B84143B0320S021 EPCOS - TDK Electronics

B84143B0320S021

LINE FILTER 760/440VAC 320A CHAS

EPCOS - TDK Electronics

2,084 -
Datasheet B84143B Bulk Active Three Phase (Delta) Two Stage - 760V, 440V - - 320 A 50 ~ 60Hz Inverters, Power Drive Systems cUL, UL - Chassis Mount Terminal Post, Threaded Post (M10) -
FLLE2030ASRW1 KEMET

FLLE2030ASRW1

LINE FILTER 480VDC 30A CHASS MNT

KEMET

1,727 -
Datasheet FLLE2-PV Bulk Last Time Buy Single Phase Single Stage 480V - - - 30 A - General Purpose UL -25°C ~ 85°C Chassis Mount Threaded Post (M6) -
Total 8635 Record«Prev1... 361362363364365366367368...432Next»
COMPONENT SOURCING SUPPORT

Need Help Finding Electronic Components?

Share your part numbers or BOM for electronic component sourcing, pricing, availability and lead-time support.

Electronic component RFQ service Component pricing & availability
FREQUENTLY ASKED QUESTIONS

Power Line Filter Modules FAQs

Answers to common questions about component sourcing and electronic component sourcing.

Can HK CSY-ELECTRONICS help source Power Line Filter Modules components?

Submit part numbers, quantities and relevant requirements through our component RFQ form. Availability and quotation details are reviewed for each request.

Can I send a BOM for component sourcing?

Yes. Provide your bill of materials with required quantities and preferred manufacturers so our team can evaluate your sourcing request.

Do you also support PCB fabrication and assembly?

Yes. Our PCB and PCBA quotation form accepts board specifications and project files for fabrication and assembly inquiries.