Power Line Filter Modules
Explore Power Line Filter Modules components, specifications, manufacturers and sourcing options.
Browse Power Line Filter Modules parts and compare technical details, inventory references and datasheets to support your electronics project.
Submit part numbers or a BOM to request component pricing, availability and sourcing support.
| Photo | Mfr. Part # | Availability | Price | Quantity | Datasheet | Series | Packaging | Product Status | Filter Type | Configuration | Voltage - Rated DC | Voltage - Rated AC | Voltage - Rated AC (Phase to Ground/Neutral) | Voltage - Rated AC (Phase to Phase) | Current | Frequency - Operating | Applications | Approval Agency | Operating Temperature | Mounting Type | Termination Style | Inductance |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
FMAC-0954-H112ILINE FILTER 480/520VAC 110A CHAS |
4,582 | - |
|
Datasheet | FMAC | Bulk | Active | Three Phase (Delta) | Single Stage | - | 480V, 520V | - | - | 110 A | 50/60Hz | Photovoltaic Inverter | cURus, ENEC, VDE | -25°C ~ 100°C | Chassis Mount | Terminal Block | 700µH |
|
RTEN-2080LINE FILTER 80A CHASSIS MOUNT |
3,405 | - |
|
Datasheet | RTEN-2 | Bulk | Active | Three Phase (Delta) | Single Stage | - | - | 250 V | 250 V | 80 A | - | General Purpose | ENEC, UL | -25°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
|
RSHN-2080LINE FILTER 250VAC/VDC 80A CHASS |
2,283 | - |
|
Datasheet | RSHN | Bulk | Active | Single Phase | Two Stage | 250V | 250V | - | - | 80 A | - | General Purpose | - | -25°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
FMCC-I93A-J834LINE FILTER 180A CHASSIS MOUNT |
4,197 | - |
|
Datasheet | FMCC SOL | Box | Active | Three Phase (Delta) | Three Stage | - | - | 520 V | 760 V | 180 A | 50 ~ 60Hz | General Purpose | cURus | -40°C ~ 100°C | Chassis Mount | Threaded Post (M10) | - |
|
200KEPS6AFPWLINE FLTR 440VAC 200A CHASS MNT |
1,139 | - |
|
Datasheet | KEP | Box | Active | Three Phase (Wye) | Single Stage | - | 440V | - | - | 200 A | 50/60Hz | Converter | CSA, UL | -25°C ~ 85°C | Chassis Mount | Threaded Post (M10) | - |
|
FN5420-26-92-E0XXTLINE FILTER 26A CHASSIS MOUNT |
4,102 | - |
|
Datasheet | FN 5420 | Bulk | Active | Three Phase (Delta) | Single Stage | - | - | 480 V | 530 V | 26 A | DC ~ 60Hz | Regenerative Motor Drive | CE, cURus, UKCA | -40°C ~ 70°C | Chassis Mount | Terminal Block | 1.7mH |
|
B84142C0400S081LINE FLTR 1500VDC 600VAC CHAS |
4,096 | - |
|
Datasheet | B84142C | Box | Active | DC | Two Stage | 1500V (1.5kV) | 600V | - | - | 400 A | - | Photovoltaic Inverter | cUR, UR | -25°C ~ 100°C | Chassis Mount | Terminal Post | - |
|
|
80AYC10BLINE FILTER 80A CHASSIS MOUNT |
3,176 | - |
|
Datasheet | AYC | Bulk | Last Time Buy | Three Phase (Wye) | Single Stage | - | - | 277 V | 480 V | 80 A | 50/60Hz | General Purpose | UR | -10°C ~ 40°C | Chassis Mount | Terminal Block | - |
|
B84143A0180R000LINE FILTER 480/275VAC 180A CHAS |
2,590 | - |
|
Datasheet | B84143A | Bulk | Active | Three Phase (Delta) | Single Stage | - | 480V, 275V | 275 V | 480 V | 180 A | 50 ~ 60Hz | Inverters, Power Drive Systems | UL | - | Chassis Mount | Terminal Block, Threaded Post (M10) | - |
|
FTA-150-104-SLINE FLTR 500VAC 150A CHASS MNT |
2,422 | - |
|
Datasheet | FTA | Box | Active | Three Phase (Wye) | Single Stage | - | 500V | - | - | 150 A | 50/60Hz | General Purpose | cURus, VDE | -40°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
FTA-150-155-SLINE FLTR 500VAC 150A CHASS MNT |
3,339 | - |
|
Datasheet | FTA | Box | Active | Three Phase (Wye) | Single Stage | - | 500V | - | - | 150 A | 50/60Hz | General Purpose | cURus, VDE | -40°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
FTA-150-223-SLINE FLTR 500VAC 150A CHASS MNT |
4,432 | - |
|
Datasheet | FTA | Box | Active | Three Phase (Wye) | Single Stage | - | 500V | - | - | 150 A | 50/60Hz | General Purpose | cURus, VDE | -40°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
FTA-150-683-SLINE FLTR 500VAC 150A CHASS MNT |
3,143 | - |
|
Datasheet | FTA | Box | Active | Three Phase (Wye) | Single Stage | - | 500V | - | - | 150 A | 50/60Hz | General Purpose | cURus, VDE | -40°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
B86301U0400S000LINE FILTER 520VAC 400A |
1,419 | - |
|
Datasheet | B86301 | Box | Active | Three Phase (Delta) | Single Stage | - | 520V | - | - | 400 A | 50/60Hz | General Purpose | cURus | -25°C ~ 100°C | - | Terminal Post | 13µH |
|
B86305L0390S000LINE FLTR 520VAC 390A CHASS MNT |
4,666 | - |
|
Datasheet | B86305 | Box | Active | Three Phase (Delta) | Single Stage | - | 520V | - | - | 390 A | 50/60Hz | Converter | cURus | -25°C ~ 100°C | Chassis Mount | Terminal Block | 75µH |
|
B84144A0200R140LINE FILTER 200A CHASSIS MOUNT |
2,073 | - |
|
Datasheet | B84144 | Box | Active | Three Phase (Wye) | Single Stage | - | - | 520 V | 300 V | 200 A | 50/60Hz | General Purpose | cUR, UR | -25°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
FN520-12-29LINE FILTER 12A CHASSIS MOUNT |
3,370 | - |
|
Datasheet | FN 520 | Tray | Obsolete | Three Phase (Delta) | Single Stage | - | - | 288 V | 500 V | 12 A | - | Regenerative Motor Drive | - | -25°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
B84143B0150S021LINE FILTER 760/440VAC 150A CHAS |
1,631 | - |
|
Datasheet | B84143B | Bulk | Active | Three Phase (Delta) | Two Stage | - | 760V, 440V | - | - | 150 A | 50 ~ 60Hz | Inverters, Power Drive Systems | cUL, UL | - | Chassis Mount | Terminal Post, Threaded Post (M10) | - |
|
B84142J0400S081LINE FLTR 1000VDC 600VAC CHAS |
1,047 | - |
|
Datasheet | B84142 | Box | Active | DC | Two Stage | 1000V (1kV) | 600V | - | - | 400 A | - | Photovoltaic Inverter | cUR, UR | -25°C ~ 100°C | Chassis Mount | Terminal Post | - |
|
FN3310-400-99-R5LINE FLTR 520VAC 400A CHASS MNT |
3,341 | - |
|
Datasheet | FN 3310 | Box | Active | Three Phase (Delta) | Single Stage | - | 520V | - | 520 V | 400 A | DC ~ 60Hz | General Purpose | CE, cURus, ENEC | -40°C ~ 100°C | Chassis Mount | Terminal Post | - |
Power Line Filter Modules FAQs
Answers to common questions about component sourcing and electronic component sourcing.
Can HK CSY-ELECTRONICS help source Power Line Filter Modules components?
Submit part numbers, quantities and relevant requirements through our component RFQ form. Availability and quotation details are reviewed for each request.
Can I send a BOM for component sourcing?
Yes. Provide your bill of materials with required quantities and preferred manufacturers so our team can evaluate your sourcing request.
Do you also support PCB fabrication and assembly?
Yes. Our PCB and PCBA quotation form accepts board specifications and project files for fabrication and assembly inquiries.