| Photo | Mfr. Part # | Availability | Price | Quantity | Datasheet | Series | Packaging | Product Status | Filter Type | Configuration | Voltage - Rated DC | Voltage - Rated AC | Voltage - Rated AC (Phase to Ground/Neutral) | Voltage - Rated AC (Phase to Phase) | Current | Frequency - Operating | Applications | Approval Agency | Operating Temperature | Mounting Type | Termination Style | Inductance |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
NAH-60-223LINE FLTR 300VDC 277VAC 60A CHAS |
4,552 | - |
|
Datasheet | NAH | Bulk | Active | Single Phase | Single Stage | 300V | 277V | - | - | 60 A | 50/60Hz | General Purpose | CSA, cURus, DEMKO, ENEC | -40°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
NAH-60-222LINE FLTR 300VDC 277VAC 60A CHAS |
1,520 | - |
|
Datasheet | NAH | Bulk | Active | Single Phase | Single Stage | 300V | 277V | - | - | 60 A | 50/60Hz | General Purpose | CSA, cURus, DEMKO, ENEC | -40°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
2948270LINE FILTER 500VAC CHASSIS MOUNT |
4,945 | - |
|
Datasheet | - | Bulk | Obsolete | Three Phase (Delta) | Single Stage | - | 500V | - | - | - | 50/60Hz | General Purpose | - | -20°C ~ 70°C | Chassis Mount | Terminal Block | 220nH |
|
3-138-373LINE FILTER 25A CHASSIS MOUNT |
3,167 | - |
|
Datasheet | FMBD EP | Box | Active | Three Phase (Wye) | Two Stage | - | - | 520 V | 760 V | 25 A | 50 ~ 60Hz | General Purpose | cURus, ENEC, VDE | -40°C ~ 100°C | Chassis Mount | Terminal Block, Threaded Post (M6) | - |
|
3-138-364LINE FILTER 25A CHASSIS MOUNT |
3,999 | - |
|
Datasheet | FMBD EP | Box | Active | Three Phase (Wye) | Two Stage | - | - | 520 V | 760 V | 25 A | 50 ~ 60Hz | General Purpose | cURus, ENEC, VDE | -40°C ~ 100°C | Chassis Mount | Terminal Block, Threaded Post (M6) | - |
|
RTEN-2040LINE FILTER 40A CHASSIS MOUNT |
1,495 | - |
|
Datasheet | RTEN-2 | Bulk | Active | Three Phase (Delta) | Single Stage | - | - | 250 V | 250 V | 40 A | - | General Purpose | ENEC, UL | -25°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
16KEPS10BBSWVMLINE FILTER 520VAC 16A CHASS MNT |
2,478 | - |
|
Datasheet | KEP-BS | Box | Active | Three Phase (Wye) | Single Stage | - | 520V | - | - | 16 A | 50 ~ 60Hz | General Purpose | CSA, UL | -25°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
NAH-50-471LINE FLTR 300VDC 277VAC 50A CHAS |
2,905 | - |
|
Datasheet | NAH | Bulk | Active | Single Phase | Single Stage | 300V | 277V | - | - | 50 A | 50/60Hz | General Purpose | CSA, cURus, DEMKO, ENEC | -40°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
FN3288HV-16-44-C25-R65LINE FILTER 16A CHASSIS MOUNT |
2,094 | - |
|
Datasheet | FN 3288 | Bulk | Active | Three Phase (Delta) | Two Stage | - | - | 440 V | 760 V | 16 A | DC ~ 60Hz | Inverters, Power Drive Systems | CE, ENEC, UKCA, UR | -40°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
FLLD3042AMHT3LINE FILTER 42A CHASSIS MOUNT |
3,950 | - |
|
Datasheet | * | Bulk | Last Time Buy | Three Phase (Delta) | Single Stage | - | - | 305 V | 530 V | 42 A | 50/60Hz | General Purpose | ENEC, UL | -25°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
3-104-585LINE FILTER 80A CHASSIS MOUNT |
4,754 | - |
|
Datasheet | FMAC NEO | Bulk | Active | Three Phase (Delta) | Single Stage | - | - | 300 V | 520 V | 80 A | 50 ~ 60Hz | General Purpose | cURus, ENEC | -40°C ~ 100°C | Chassis Mount | Terminal Block, Threaded Post (M6) | - |
|
3-138-360LINE FILTER 36A CHASSIS MOUNT |
4,489 | - |
|
Datasheet | FMBD EP | Box | Active | Three Phase (Wye) | Two Stage | - | - | 520 V | 760 V | 36 A | 50 ~ 60Hz | General Purpose | cURus, ENEC, VDE | -40°C ~ 100°C | Chassis Mount | Terminal Block, Threaded Post (M6) | - |
|
TKA-055LINE FILTER 440VAC 55A CHASS MNT |
3,183 | - |
|
Datasheet | TK | Box | Obsolete | Three Phase (Delta) | Single Stage | - | 440V | - | - | 55 A | 50/60Hz | Inverters, Power Drive Systems | cCSAus, CE, UR | -25°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
15KEBS6AFPDDMLINE FILTER 440VAC 15A CHASS MNT |
1,450 | - |
|
Datasheet | KEB | Box | Active | Three Phase (Delta) | Single Stage | - | 440V | - | - | 15 A | 50 ~ 60Hz | General Purpose | CSA, UL | -25°C ~ 85°C | Chassis Mount | Threaded Post (M5) | - |
|
FMBD-345B-6414LINE FILTER 760VAC 64A CHASS MNT |
4,702 | - |
|
Datasheet | FMBD EP | Box | Active | Three Phase (Wye) | Two Stage | - | 760V | - | - | 64 A | 50/60Hz | General Purpose | cURus, ENEC, UL, VDE | -40°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
TAH-30-683-DLINE FILTER 500VAC 30A DIN RAIL |
2,161 | - |
|
Datasheet | TAH | Box | Active | Three Phase (Wye) | Single Stage | - | 500V | - | - | 30 A | 50/60Hz | General Purpose | cURus, VDE | -40°C ~ 85°C | DIN Rail | Terminal Block | - |
|
FLLD3030AMHT3LINE FILTER 30A CHASSIS MOUNT |
3,699 | - |
|
Datasheet | * | Bulk | Active | Three Phase (Delta) | Single Stage | - | - | 305 V | 530 V | 30 A | 50/60Hz | General Purpose | ENEC, UL | -25°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
RTCN-5060LINE FILTER 500VAC/VDC 60A CHASS |
3,011 | - |
|
Datasheet | RTCN | Bulk | Active | Three Phase (Delta) | Single Stage | 500V | 500V | - | - | 60 A | - | General Purpose | EN, UL | -25°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
|
36TYT8-1LINE FILTER 520VAC CHASSIS MOUNT |
2,960 | - |
|
Datasheet | TYT | Box | Active | Three Phase (Wye) | Single Stage | - | 520V | - | - | - | 50/60Hz | General Purpose | UR | - | Chassis Mount | Terminal Block | 1mH |
|
3-138-361LINE FILTER 50A CHASSIS MOUNT |
4,765 | - |
|
Datasheet | FMBD EP | Box | Active | Three Phase (Wye) | Two Stage | - | - | 520 V | 760 V | 50 A | 50 ~ 60Hz | General Purpose | cURus, ENEC, VDE | -40°C ~ 100°C | Chassis Mount | Terminal Block, Threaded Post (M6) | - |
Power Line Filter Modules FAQs
Answers to common questions about component sourcing and electronic component sourcing.
Can HK CSY-ELECTRONICS help source Power Line Filter Modules components?
Submit part numbers, quantities and relevant requirements through our component RFQ form. Availability and quotation details are reviewed for each request.
Can I send a BOM for component sourcing?
Yes. Provide your bill of materials with required quantities and preferred manufacturers so our team can evaluate your sourcing request.
Do you also support PCB fabrication and assembly?
Yes. Our PCB and PCBA quotation form accepts board specifications and project files for fabrication and assembly inquiries.