Power Line Filter Modules
Explore Power Line Filter Modules components, specifications, manufacturers and sourcing options.
Browse Power Line Filter Modules parts and compare technical details, inventory references and datasheets to support your electronics project.
Submit part numbers or a BOM to request component pricing, availability and sourcing support.
| Photo | Mfr. Part # | Availability | Price | Quantity | Datasheet | Series | Packaging | Product Status | Filter Type | Configuration | Voltage - Rated DC | Voltage - Rated AC | Voltage - Rated AC (Phase to Ground/Neutral) | Voltage - Rated AC (Phase to Phase) | Current | Frequency - Operating | Applications | Approval Agency | Operating Temperature | Mounting Type | Termination Style | Inductance |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
FSB-40-324LINE FILTER 500VAC 40A CHASS MNT |
2,230 | - |
|
Datasheet | FSB | Box | Active | Three Phase (Delta) | Two Stage | - | 500V | - | - | 40 A | 50/60Hz | General Purpose | cURus, VDE | -40°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
FMBD-395D-K314LINE FLTR 760VAC 230A CHASS MNT |
2,032 | - |
|
Datasheet | FMBD EP | Box | Active | Three Phase (Wye) | Two Stage | - | 760V | - | - | 230 A | 50/60Hz | General Purpose | cURus, ENEC, UL, VDE | -40°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
|
80KEBS10BFPDLINE FILTER 520VAC 80A CHASS MNT |
2,906 | - |
|
Datasheet | KEB | Box | Active | Three Phase (Delta) | Single Stage | - | 520V | - | - | 80 A | 50/60Hz | General Purpose | CSA, UL | -25°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
75BCF6RLINE FILTER 75A CHASSIS MOUNT |
1,854 | - |
|
Datasheet | BCFXR | Box | Active | Three Phase (Delta) | Two Stage | - | - | 277 V | 480 V | 75 A | 50/60Hz | General Purpose | CSA, UR, VDE | -10°C ~ 50°C | Chassis Mount | Threaded Post (M5) | 1.06mH |
|
FMAD-0953-6410LINE FILTER 277V/480VAC 64A CHAS |
2,470 | - |
|
Datasheet | FMAD | Bag | Active | Three Phase (Wye) | Single Stage | - | 277V, 480V | - | - | 64 A | 50/60Hz | General Purpose | cURus, VDE | -25°C ~ 100°C | Chassis Mount | Terminal Block | 600µH |
|
100KEHD10AFPDLINE FLTR 440VAC 100A CHASS MNT |
3,552 | - |
|
Datasheet | KEH | Box | Active | Three Phase (Delta) | Two Stage | - | 440V | - | - | 100 A | 50/60Hz | General Purpose | CSA, UL | -25°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
B84143V0016R229LINE FILTER 16A CHASSIS MOUNT |
3,197 | - |
|
Datasheet | B84143V | Box | Active | Three Phase (Delta) | Single Stage | - | - | 300 V | 520 V | 16 A | 50/60Hz | General Purpose | cURus | -25°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
FN5045-8-44LINE FILTER 8A CHASSIS MOUNT |
4,330 | - |
|
Datasheet | FN 5045 | Box | Obsolete | Three Phase (Delta) | Single Stage | - | - | - | - | 8 A | - | Regenerative Motor Drive | cURus | -25°C ~ 70°C | Chassis Mount | Terminal Block | 6.9mH |
|
DE60-4FFLINE FILTER 480VAC 60A CHASS MNT |
1,256 | - |
|
Datasheet | DE | Box | Active | Three Phase (Delta) | Two Stage | - | 480V | 2 kV | - | 60 A | 47Hz, 63Hz | General Purpose | - | - | Chassis Mount | Threaded Post (1/4-20) | - |
|
100KEVD10BBSWLINE FLTR 520VAC 100A CHASS MNT |
3,062 | - |
|
Datasheet | KEV-BS | Box | Active | Three Phase (Wye) | Two Stage | - | 520V | - | - | 100 A | 50/60Hz | General Purpose | CSA, UL | -25°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
FMAC-0A38-3213LINE FILTER 550VAC 32A CHASS MNT |
1,868 | - |
|
Datasheet | FMAC-Out | Bulk | Active | Three Phase (Delta) | Single Stage | - | 550V | - | - | 32 A | 50/60Hz | General Purpose | cURus, ENEC, VDE | -25°C ~ 100°C | Chassis Mount | Terminal Block | 200µH |
|
120KEMS10ABSDLINE FLTR 440VAC 120A CHASS MNT |
1,317 | - |
|
Datasheet | KEM-BS | Box | Active | Three Phase (Delta) | Single Stage | - | 440V | - | - | 120 A | 50/60Hz | General Purpose | CSA, UL | -25°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
150KEPS10ABSWLINE FLTR 440VAC 150A CHASS MNT |
4,402 | - |
|
Datasheet | KEP-BS | Box | Active | Three Phase (Wye) | Single Stage | - | 440V | - | - | 150 A | 50/60Hz | General Purpose | CSA, UL | -25°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
FMBC-0937-6410LINE FILTER 480VAC 64A CHASS MNT |
4,574 | - |
|
Datasheet | FMBC | Bag | Active | Three Phase (Delta) | Two Stage | - | 480V | - | - | 64 A | 50/60Hz | General Purpose | cURus, ENEC, VDE | -25°C ~ 100°C | Chassis Mount | Terminal Block | 850µH |
|
FMBC-0938-5010LINE FILTER 480VAC 50A CHASS MNT |
1,057 | - |
|
Datasheet | FMBC | Bulk | Active | Three Phase (Delta) | Two Stage | - | 480V | - | - | 50 A | 50/60Hz | General Purpose | cURus, ENEC, VDE | -25°C ~ 100°C | Chassis Mount | Terminal Block | 1mH |
|
FMBC-A91G-J310LINE FILTER 480/520VAC 130A CHAS |
4,268 | - |
|
Datasheet | FMBC NEO | Bulk | Active | Three Phase (Delta) | Two Stage | - | 480V, 520V | - | - | 130 A | 50/60Hz | General Purpose | cURus, ENEC, VDE | -25°C ~ 100°C | Chassis Mount | Terminal Block | L1 - 700µH, L2 - 26µH |
|
120KEHD10BBSDLINE FLTR 520VAC 120A CHASS MNT |
3,080 | - |
|
Datasheet | KEH-BS | Box | Active | Three Phase (Delta) | Two Stage | - | 520V | - | - | 120 A | 50/60Hz | General Purpose | CSA, UL | -25°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
FMAD-0937-8010LINE FILTER 277V/480VAC 80A CHAS |
2,617 | - |
|
Datasheet | FMAD | Bag | Active | Three Phase (Wye) | Single Stage | - | 277V, 480V | - | - | 80 A | 50/60Hz | General Purpose | cURus, VDE | -25°C ~ 100°C | Chassis Mount | Terminal Block | 900µH |
|
FMAC-0954-H110LINE FILTER 480/520VAC 110A CHAS |
3,282 | - |
|
Datasheet | FMAC | Bag | Active | Three Phase (Delta) | Single Stage | - | 480V, 520V | - | - | 110 A | 50/60Hz | Photovoltaic Inverter | cURus, ENEC, VDE | -25°C ~ 100°C | Chassis Mount | Terminal Block | 700µH |
|
125 AHV S FPLINE FILTER 125A CHASSIS MOUNT |
3,231 | - |
|
Datasheet | AHV | Box | Active | Three Phase (Delta) | Single Stage | - | - | 750 V | 760 V | 125 A | 50Hz ~ 60Hz | General Purpose | cURus | -25°C ~ 85°C | Chassis Mount | Quick Connect | - |
Power Line Filter Modules FAQs
Answers to common questions about component sourcing and electronic component sourcing.
Can HK CSY-ELECTRONICS help source Power Line Filter Modules components?
Submit part numbers, quantities and relevant requirements through our component RFQ form. Availability and quotation details are reviewed for each request.
Can I send a BOM for component sourcing?
Yes. Provide your bill of materials with required quantities and preferred manufacturers so our team can evaluate your sourcing request.
Do you also support PCB fabrication and assembly?
Yes. Our PCB and PCBA quotation form accepts board specifications and project files for fabrication and assembly inquiries.