PRODUCT CATEGORIES

Power Line Filter Modules

Explore Power Line Filter Modules components, specifications, manufacturers and sourcing options.

Browse Power Line Filter Modules parts and compare technical details, inventory references and datasheets to support your electronics project.

Submit part numbers or a BOM to request component pricing, availability and sourcing support.

Photo Mfr. Part # Availability Price Quantity Datasheet Series Packaging Product Status Filter Type Configuration Voltage - Rated DC Voltage - Rated AC Voltage - Rated AC (Phase to Ground/Neutral) Voltage - Rated AC (Phase to Phase) Current Frequency - Operating Applications Approval Agency Operating Temperature Mounting Type Termination Style Inductance
4-1609037-1 TE Connectivity Corcom Filters

4-1609037-1

LINE FILTER 250VAC 20A CHASS MNT

TE Connectivity Corcom Filters

4,433 -
Datasheet HQ Box Active Single Phase Two Stage - 250V - - 20 A 50/60Hz General Purpose CSA, UR, VDE -10°C ~ 40°C Chassis Mount Threaded Post (8-32) 6mH
20TDS6D Delta Electronics

20TDS6D

LINE FILTER 440VAC 20A CHASS MNT

Delta Electronics

3,971 -
Datasheet TD Box Active Three Phase (Delta) Two Stage - 440V - - 20 A 50/60Hz General Purpose - - Chassis Mount Threaded Post (M6) L1 - 78µH, L2 - 1.6mH
FMBD-345A-2514 SCHURTER Inc.

FMBD-345A-2514

LINE FILTER 760VAC 25A CHASS MNT

SCHURTER Inc.

2,375 -
Datasheet FMBD EP Box Active Three Phase (Wye) Two Stage - 760V - - 25 A 50/60Hz General Purpose cURus, ENEC, UL, VDE -40°C ~ 100°C Chassis Mount Terminal Block -
LF-215U KEMET

LF-215U

LINE FILTER 250VAC/VDC 15A CHASS

KEMET

4,583 -
Datasheet LF Box Obsolete Single Phase Two Stage 250V 250V - - 15 A - General Purpose UL -20°C ~ 55°C Chassis Mount Threaded Post (M4) -
TB6-B016NBDC DIT

TB6-B016NBDC

LINE FILTER 16A CHASSIS MOUNT

DIT

3,900 -
Datasheet TB6-B Box Active Three Phase (Delta) Two Stage - - 254 V 440 V 16 A 50 ~ 60Hz General Purpose CE, CSA, ENEC, SEMKO -25°C ~ 100°C Chassis Mount Terminal Block -
TB6-B020NBDC DIT

TB6-B020NBDC

LINE FILTER 20A CHASSIS MOUNT

DIT

4,370 -
Datasheet TB6-B Box Active Three Phase (Delta) Two Stage - - 254 V 440 V 20 A 50 ~ 60Hz General Purpose CE, CSA, ENEC, SEMKO -25°C ~ 100°C Chassis Mount Terminal Block -
TB6-B030NBDC DIT

TB6-B030NBDC

LINE FILTER 30A CHASSIS MOUNT

DIT

3,838 -
Datasheet TB6-B Box Active Three Phase (Delta) Two Stage - - 254 V 440 V 30 A 50 ~ 60Hz General Purpose CE, CSA, ENEC, SEMKO -25°C ~ 100°C Chassis Mount Terminal Block -
2-6609074-1 TE Connectivity Corcom Filters

2-6609074-1

LINE FILTER 80VDC 15A CHASS MNT

TE Connectivity Corcom Filters

2,548 -
Datasheet DC Bulk Active DC Single Stage 80V - - - 15 A - General Purpose CSA, TUV, UL -10°C ~ 55°C Chassis Mount Threaded Post (10-32) -
3-1609037-7 TE Connectivity Corcom Filters

3-1609037-7

LINE FILTER 250VAC 20A CHASS MNT

TE Connectivity Corcom Filters

1,936 -
Datasheet HQ Bulk Active Single Phase Two Stage - 250V - - 20 A 50 ~ 60Hz Medical UL, VDE - Chassis Mount - -
TB6-5030D3DG DIT

TB6-5030D3DG

LINE FILTER 30A CHASSIS MOUNT

DIT

1,801 -
Datasheet TB6-2,5 G/H Box Active Three Phase (Delta) Two Stage - - 290 V 500 V 30 A 50 ~ 60Hz General Purpose CE, ENEC, SEMKO, UL, UR - Chassis Mount Terminal Block -
RCY6G-30 R-K Electronics, Inc.

RCY6G-30

LINE FILTER 600VAC SURFACE MOUNT

R-K Electronics, Inc.

4,824 -
Datasheet - Box Active Three Phase (Wye) - - 600V - - - 50 ~ 60Hz General Purpose cURus -40°C ~ 85°C Surface Mount Wire Leads -
BK2AA105B KYOCERA AVX

BK2AA105B

LINE FILTER 15A CHASSIS MOUNT

KYOCERA AVX

3,359 -
Datasheet BK Bulk Active Signal Line - - - - - 15 A - - - - Chassis Mount Quick Connect -
RCD5A-30 R-K Electronics, Inc.

RCD5A-30

LINE FILTER 480VAC SURFACE MOUNT

R-K Electronics, Inc.

1,081 -
Datasheet - Bulk Active Three Phase (Delta) - - 480V - - - 50 ~ 60Hz General Purpose cURus -40°C ~ 60°C Surface Mount Wire Leads -
RCD5G-30 R-K Electronics, Inc.

RCD5G-30

LINE FILTER 480VAC SURFACE MOUNT

R-K Electronics, Inc.

2,658 -
Datasheet - Bulk Active Three Phase (Delta) - - 480V - - - 50 ~ 60Hz General Purpose cURus -40°C ~ 60°C Surface Mount Wire Leads -
RCD2A-30 R-K Electronics, Inc.

RCD2A-30

LINE FILTER 240VAC SURFACE MOUNT

R-K Electronics, Inc.

4,682 -
Datasheet - Bulk Active Three Phase (Delta) - - 240V - - - 50 ~ 60Hz General Purpose cURus -40°C ~ 60°C Surface Mount Wire Leads -
TB6-5010D3DG DIT

TB6-5010D3DG

LINE FILTER 10A CHASSIS MOUNT

DIT

1,326 -
Datasheet TB6-2,5 G/H Box Active Three Phase (Delta) Two Stage - - 290 V 500 V 10 A 50 ~ 60Hz General Purpose CE, ENEC, SEMKO, UL, UR - Chassis Mount Terminal Block -
TB6-5016D3DG DIT

TB6-5016D3DG

LINE FILTER 16A CHASSIS MOUNT

DIT

3,825 -
Datasheet TB6-2,5 G/H Box Active Three Phase (Delta) Two Stage - - 290 V 500 V 16 A 50 ~ 60Hz General Purpose CE, ENEC, SEMKO, UL, UR - Chassis Mount Terminal Block -
7BCF10 TE Connectivity Corcom Filters

7BCF10

LINE FILTER 7A CHASSIS MOUNT

TE Connectivity Corcom Filters

4,227 -
Datasheet BCF Box Last Time Buy Three Phase (Delta) Two Stage - - 277 V 480 V 7 A 50/60Hz Inverters, Power Drive Systems UR, VDE -10°C ~ 50°C Chassis Mount Terminal Block -
2-1609091-5 TE Connectivity Corcom Filters

2-1609091-5

LINE FILTER 7A CHASSIS MOUNT

TE Connectivity Corcom Filters

2,846 -
Datasheet BCF Box Last Time Buy Three Phase (Delta) Two Stage - - 277 V 480 V 7 A 50/60Hz Inverters, Power Drive Systems UR, VDE -10°C ~ 50°C Chassis Mount Threaded Post (M5) -
FLLDU040A225I0 KEMET

FLLDU040A225I0

LINE FLTR 440VDC 250VAC 40A CHAS

KEMET

1,693 -
Datasheet FLLDU Bulk Last Time Buy Single Phase Single Stage 440V 250V - - 40 A 50/60Hz General Purpose UR -40°C ~ 85°C Chassis Mount Threaded Post (M6) -
Total 8635 Record«Prev1... 130131132133134135136137...432Next»
COMPONENT SOURCING SUPPORT

Need Help Finding Electronic Components?

Share your part numbers or BOM for electronic component sourcing, pricing, availability and lead-time support.

Electronic component RFQ service Component pricing & availability
FREQUENTLY ASKED QUESTIONS

Power Line Filter Modules FAQs

Answers to common questions about component sourcing and electronic component sourcing.

Can HK CSY-ELECTRONICS help source Power Line Filter Modules components?

Submit part numbers, quantities and relevant requirements through our component RFQ form. Availability and quotation details are reviewed for each request.

Can I send a BOM for component sourcing?

Yes. Provide your bill of materials with required quantities and preferred manufacturers so our team can evaluate your sourcing request.

Do you also support PCB fabrication and assembly?

Yes. Our PCB and PCBA quotation form accepts board specifications and project files for fabrication and assembly inquiries.