Current Sensors
Explore Current Sensors components, specifications, manufacturers and sourcing options.
Browse Current Sensors parts and compare technical details, inventory references and datasheets to support your electronics project.
Submit part numbers or a BOM to request component pricing, availability and sourcing support.
| Photo | Mfr. Part # | Availability | Price | Quantity | Datasheet | Series | Package/Case | Packaging | Product Status | For Measuring | Sensor Type | Current - Sensing | Number of Channels | Output | Sensitivity | Frequency | Linearity | Accuracy | Voltage - Supply | Response Time | Current - Supply (Max) | Operating Temperature | Grade | Qualification | Polarization | Mounting Type | Supplier Device Package |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
SCT-0400-0250.4" SPLIT-CORE CT 25A:333MV |
2,138 | - |
|
Datasheet | SCT-0400 | Module, Single Pass Through | Bag | Active | AC | Current Sensor | 25A | 1 | Ratiometric, Voltage | - | 50Hz ~ 1kHz | ±1% | ±1% | - | - | - | -20°C ~ 75°C | - | - | Unidirectional | Free Hanging | - |
|
SCT-0400-0600.4" SPLIT-CORE CT 60A:333MV |
2,853 | - |
|
Datasheet | SCT-0400 | Module, Single Pass Through | Bag | Active | AC | Current Sensor | 60A | 1 | Ratiometric, Voltage | - | 50Hz ~ 1kHz | ±1% | ±1% | - | - | - | -20°C ~ 75°C | - | - | Unidirectional | Free Hanging | - |
|
SCT-0400-0750.4" SPLIT-CORE CT 75A:333MV |
3,041 | - |
|
Datasheet | SCT-0400 | Module, Single Pass Through | Bag | Active | AC | Current Sensor | 75A | 1 | Ratiometric, Voltage | - | 50Hz ~ 1kHz | ±1% | ±1% | - | - | - | -20°C ~ 75°C | - | - | Unidirectional | Free Hanging | - |
|
SCT-0400-0150.4" SPLIT-CORE CT 15A:333MV |
2,344 | - |
|
Datasheet | SCT-0400 | Module, Single Pass Through | Bag | Active | AC | Current Sensor | 15A | 1 | Ratiometric, Voltage | - | 50Hz ~ 1kHz | ±1% | ±1% | - | - | - | -20°C ~ 75°C | - | - | Unidirectional | Free Hanging | - |
|
ACI-0.5-PAC CURRENT INDICATOR, REMOTE LED |
1,160 | - |
|
Datasheet | AMPFlasher™ ACI | Module | Box | Active | AC | Current Indicator | 500mA | 1 | LED | - | 50Hz ~ 400Hz | - | - | - | - | - | -20°C ~ 50°C | - | - | Unidirectional | Chassis Mount | - |
|
|
CSNE151-204SENSOR CURRENT HALL 90A AC/DC |
4,251 | - |
|
Datasheet | CSN | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Closed Loop | 90A | 1 | Ratiometric, Current | - | DC ~ 150kHz | ±0.2% | ±0.5% | ±15V | 1µs | 10mA | 0°C ~ 70°C | - | - | Bidirectional | Through Hole | - |
|
351-2CURRENT SENSOR: 0.2 TO 2 AMPS |
3,776 | - |
|
Datasheet | 300 | Module | Box | Active | AC/DC | Current Sensor | 2A | 3 | Relay, SPDT | - | 50Hz/60Hz | - | ±5% | 24V ~ 240V | - | - | -20°C ~ 55°C | - | - | - | DIN Rail | - |
|
ATM2802-HLEAKAGE SENSOR,AC-30MA/DC-6MA |
3,890 | - |
|
Datasheet | - | Module, Single Pass Through | Tray | Active | AC/DC | Flux Gate | 20A, 40A | 1 | Ratiometric, Current | - | - | - | - | 4.75V ~ 5.25V | - | - | -40°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
|
|
CSLA2EJSENSOR CURRENT HALL 310A AC/DC |
2,058 | - |
|
Datasheet | CSLA | Module, Single Pass Through | Bulk | Obsolete | AC/DC | Hall Effect, Open Loop | 310A | 1 | Ratiometric, Voltage | 7.6mV/N | - | - | - | 6V ~ 12V | 3µs | 20mA | -25°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
|
20320800101CURRENT SENSOR HAN OPEN LOOP 800 |
1,193 | - |
|
Datasheet | - | - | Bulk | Obsolete | AC/DC | Current Sensor | 800A | - | - | - | DC ~ 50kHz | - | - | - | - | - | -25°C ~ 85°C | - | - | - | Chassis Mount | - |
|
DCS16P5A-CL42016MM SPLIT-CORE TRUE RMS 5A 4-20 |
1,502 | - |
|
Datasheet | DCS | Module, Single Pass Through | Bulk | Active | AC | Current Transducer | 5A | 1 | Analog Current, 4mA ~ 20mA | - | DC, 50Hz ~ 400Hz | - | ±2% | 20V ~ 30V | - | - | -20°C ~ 80°C | - | - | Unidirectional | Chassis Mount | - |
|
|
CSLA2DJSENSOR CURRENT HALL 225A AC/DC |
2,034 | - |
|
Datasheet | CSLA | Module, Single Pass Through | Bulk | Obsolete | AC/DC | Hall Effect, Open Loop | 225A | 1 | Ratiometric, Voltage | 8.7mV/N | - | - | - | 6V ~ 12V | 3µs | 20mA | -25°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
|
DCS24P200A-CL42024MM SPLIT-CORE TRUE RMS 200A 4- |
1,494 | - |
|
Datasheet | DCS | Module, Single Pass Through | Bulk | Active | AC | Current Transducer | 200A | 1 | Analog Current, 4mA ~ 20mA | - | DC, 50Hz ~ 400Hz | - | ±2% | 20V ~ 30V | - | - | -20°C ~ 80°C | - | - | Unidirectional | Chassis Mount | - |
|
DCS24P5A-CL42024MM SPLIT-CORE TRUE RMS 5A 4-20 |
1,965 | - |
|
Datasheet | DCS | Module, Single Pass Through | Bulk | Active | AC | Current Transducer | 5A | 1 | Analog Current, 4mA ~ 20mA | - | DC, 50Hz ~ 400Hz | - | ±2% | 20V ~ 30V | - | - | -20°C ~ 80°C | - | - | Unidirectional | Chassis Mount | - |
|
DCS24P30A-CL42024MM SPLIT-CORE TRUE RMS 30A 4-2 |
4,344 | - |
|
Datasheet | DCS | Module, Single Pass Through | Bulk | Active | AC | Current Transducer | 30A | 1 | Analog Current, 4mA ~ 20mA | - | DC, 50Hz ~ 400Hz | - | ±2% | 20V ~ 30V | - | - | -20°C ~ 80°C | - | - | Unidirectional | Chassis Mount | - |
|
DCS24P50A-CL42024MM SPLIT-CORE TRUE RMS 50A 4-2 |
2,826 | - |
|
Datasheet | DCS | Module, Single Pass Through | Bulk | Active | AC | Current Transducer | 50A | 1 | Analog Current, 4mA ~ 20mA | - | DC, 50Hz ~ 400Hz | - | ±2% | 20V ~ 30V | - | - | -20°C ~ 80°C | - | - | Unidirectional | Chassis Mount | - |
|
DCS24P250A-CL42024MM SPLIT-CORE TRUE RMS 250A 4- |
4,100 | - |
|
Datasheet | DCS | Module, Single Pass Through | Bulk | Active | AC | Current Transducer | 250A | 1 | Analog Current, 4mA ~ 20mA | - | DC, 50Hz ~ 400Hz | - | ±2% | 20V ~ 30V | - | - | -20°C ~ 80°C | - | - | Unidirectional | Chassis Mount | - |
|
DCS24P150A-CL42024MM SPLIT-CORE TRUE RMS 150A 4- |
3,021 | - |
|
Datasheet | DCS | Module, Single Pass Through | Bulk | Active | AC | Current Transducer | 150A | 1 | Analog Current, 4mA ~ 20mA | - | DC, 50Hz ~ 400Hz | - | ±2% | 20V ~ 30V | - | - | -20°C ~ 80°C | - | - | Unidirectional | Chassis Mount | - |
|
DCS24P10A-CL42024MM SPLIT-CORE TRUE RMS 10A 4-2 |
1,807 | - |
|
Datasheet | DCS | Module, Single Pass Through | Bulk | Active | AC | Current Transducer | 10A | 1 | Analog Current, 4mA ~ 20mA | - | DC, 50Hz ~ 400Hz | - | ±2% | 20V ~ 30V | - | - | -20°C ~ 80°C | - | - | Unidirectional | Chassis Mount | - |
|
DCS24P75A-CL42024MM SPLIT-CORE TRUE RMS 75A 4-2 |
2,972 | - |
|
Datasheet | DCS | Module, Single Pass Through | Bulk | Active | AC | Current Transducer | 75A | 1 | Analog Current, 4mA ~ 20mA | - | DC, 50Hz ~ 400Hz | - | ±2% | 20V ~ 30V | - | - | -20°C ~ 80°C | - | - | Unidirectional | Chassis Mount | - |
Current Sensors FAQs
Answers to common questions about component sourcing and electronic component sourcing.
Can HK CSY-ELECTRONICS help source Current Sensors components?
Submit part numbers, quantities and relevant requirements through our component RFQ form. Availability and quotation details are reviewed for each request.
Can I send a BOM for component sourcing?
Yes. Provide your bill of materials with required quantities and preferred manufacturers so our team can evaluate your sourcing request.
Do you also support PCB fabrication and assembly?
Yes. Our PCB and PCBA quotation form accepts board specifications and project files for fabrication and assembly inquiries.