| Photo | Mfr. Part # | Availability | Price | Quantity | Datasheet | Series | Package/Case | Packaging | Product Status | For Measuring | Sensor Type | Current - Sensing | Number of Channels | Output | Sensitivity | Frequency | Linearity | Accuracy | Voltage - Supply | Response Time | Current - Supply (Max) | Operating Temperature | Grade | Qualification | Polarization | Mounting Type | Supplier Device Package |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
DS400IDCURRENT TRANSDUCER 400A |
4,919 | - |
|
Datasheet | DS | Module, Single Pass Through | Bulk | Active | AC/DC | Flux Gate, Closed Loop | 400A | 1 | - | - | DC ~ 300kHz | ±0.00015% | - | ±14.25V ~ 15.75V | 1µs | 104mA | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
DS300IDCURRENT TRANSDUCER 300A |
4,812 | - |
|
Datasheet | DS | Module, Single Pass Through | Bulk | Active | AC/DC | Flux Gate, Closed Loop | 300A | 1 | - | - | DC ~ 1MHz | ±0.00015% | - | ±14.25V ~ 15.75V | 1µs | 104mA | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
DS600IDCURRENT TRANSDUCER 600A |
3,984 | - |
|
Datasheet | DS | Module, Single Pass Through | Bulk | Active | AC/DC | Flux Gate, Closed Loop | 600A | 1 | - | - | DC ~ 500kHz | ±0.0001% | - | ±14.25V ~ 15.75V | 1µs | 104mA | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
DS200UB-10VCURRENT TRANSDUCER 200A |
2,717 | - |
|
Datasheet | DS | Module, Single Pass Through | Bulk | Active | AC/DC | Flux Gate, Closed Loop | 200A | 1 | Ratiometric, Voltage | - | DC ~ 500kHz | ±0.005% | - | ±14.25V ~ 15.75V | 1µs | 104mA | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
DS400UB-10VCURRENT TRANSDUCER 400A |
1,125 | - |
|
Datasheet | DS | Module, Single Pass Through | Bulk | Active | AC/DC | Flux Gate, Closed Loop | 400A | 1 | - | - | DC ~ 500kHz | ±0.0015% | - | ±14.25V ~ 15.75V | 1µs | 104mA | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
DS600UB-10VCURRENT TRANSDUCER 600A |
2,042 | - |
|
Datasheet | DS | Module, Single Pass Through | Bulk | Active | AC/DC | Flux Gate, Closed Loop | 600A | 1 | Ratiometric, Voltage | - | DC ~ 300kHz | ±0.004% | - | ±14.25V ~ 15.75V | 1µs | 104mA | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
DN1000ID1000A CURRENT TRANSDUCER CURRENT |
3,003 | - |
|
Datasheet | DN | Module, Single Pass Through | Bulk | Active | AC/DC | Flux Gate, Closed Loop | 1000A | 1 | Ratiometric, Current | - | 31.25kHz | - | - | 14.25V ~ 15.75V | 1µs | 1.1A | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
DS1000UB-10VCURRENT TRANSDUCER 1000A |
3,822 | - |
|
Datasheet | DS | Module, Single Pass Through | Bulk | Active | AC/DC | Flux Gate, Closed Loop | 1000A | 1 | Ratiometric, Voltage | - | DC ~ 300kHz | ±0.0035% | - | ±14.25V ~ 15.75V | 1µs | 104mA | -40°C ~ 55°C | - | - | Bidirectional | Chassis Mount | - |
|
IN 1000-S1000A ULTRA ACCURACY |
1,471 | - |
|
Datasheet | IN | Module, Single Pass Through | Box | Active | AC/DC | Flux Gate, Closed Loop | 1000A | 1 | Current | - | DC ~ 440kHz | ±0.0002% | - | ±14.25V ~ 15.75V | 1µs | 1.12A (Typ) | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
DM1200IDCURRENT TRANSDUCER 1200A |
1,929 | - |
|
Datasheet | DM | Module, Single Pass Through | Bulk | Active | AC/DC | Flux Gate, Closed Loop | 1200A | 1 | Ratiometric, Current | - | DC ~ 300kHz | ±0.0001% | - | ±14.25V ~ 15.75V | 1µs | 120mA | -40°C ~ 65°C | - | - | Bidirectional | Chassis Mount | - |
|
IN 2000-S2000A ULTRA ACCURACY |
2,891 | - |
|
Datasheet | IN | Module, Single Pass Through | Box | Active | AC/DC | Flux Gate, Closed Loop | 2000A | 1 | Current | - | DC ~ 140kHz | ±0.0002% | - | ±14.25V ~ 15.75V | 1µs | 1.725A | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
MCS1802GS-40-P3.3V, LINEAR HALL-EFFECT CURRENT |
4,243 | - |
|
Datasheet | - | 8-SOIC (0.154", 3.90mm Width) | Tape & Reel (TR) | Active | AC/DC | Hall Effect | 40A | 1 | Ratiometric, Voltage | 33mV/A | 100kHz | ±0.5% | ±2.5% | 3V ~ 3.6V | 5µs | 10.5mA | -40°C ~ 125°C (TJ) | - | - | Bidirectional | Surface Mount | 8-SOIC |
|
HO 150-NP-0100SENSOR CURRENT HALL 150A AC/DC |
1,944 | - |
|
Datasheet | HO-NP | Module | Tray | Active | AC/DC | Hall Effect, Open Loop | 150A | 1 | Ratiometric, Voltage | - | DC ~ 350kHz | ±0.4% | ±1.2% | 5V | 2.5µs | 25mA | -40°C ~ 105°C | - | - | Bidirectional | Through Hole | - |
|
HOB 75-P/SP11 MHZ OPEN-LOOP CURRENT SENSOR 7 |
1,702 | - |
|
Datasheet | HOB-P/SP1 | Module | Bulk | Active | AC/DC | Open Loop | 75A | 1 | Voltage | 21.333mV/A | 1MHz | ±0.6% | - | 4.6V ~ 5.5V | - | 26mA | -40°C ~ 105°C | - | - | Bidirectional | Through Hole | - |
|
HOB 130-P/SP331 MHZ OPEN-LOOP CURRENT SENSOR 1 |
3,947 | - |
|
Datasheet | HOB-P/SP33 | Module | Bulk | Active | AC/DC | Open Loop | 130A | 1 | Voltage | 4.6mV/A | 1MHz | ±0.45% | - | 3.14V ~ 3.46V | - | 24mA | -40°C ~ 105°C | - | - | Bidirectional | Through Hole | - |
|
HOB 50-P1 MHZ OPEN-LOOP CURRENT SENSOR 5 |
2,671 | - |
|
Datasheet | HOB-P | Module | Bulk | Active | AC/DC | Open Loop | 50A | 1 | Voltage | 16mV/A | 1MHz | ±0.7% | - | 4.6V ~ 5.5V | 200ns | 26mA | -40°C ~ 105°C | - | - | Bidirectional | Through Hole | - |
|
HOB 50-P/SP331 MHZ OPEN-LOOP CURRENT SENSOR 5 |
2,876 | - |
|
Datasheet | HOB-P/SP33 | Module | Bulk | Active | AC/DC | Open Loop | 50A | 1 | Voltage | 9.2mV/A | 1MHz | ±0.7% | - | 3.14V ~ 3.46V | - | 24mA | -40°C ~ 105°C | - | - | Bidirectional | Through Hole | - |
|
HO 120-PSENSOR CURRENT HALL 120A AC/DC |
4,108 | - |
|
Datasheet | HO-P | Module, Single Pass Through | Tray | Active | AC/DC | Hall Effect, Open Loop | 120A | 1 | Ratiometric, Voltage (Selectable) | - | DC ~ 100kHz | ±0.5% | ±1% | 5V | 3.5µs | 25mA | -40°C ~ 105°C | - | - | Bidirectional | Through Hole | - |
|
HO 100-PSENSOR CURRENT HALL 100A AC/DC |
3,193 | - |
|
Datasheet | HO-P | Module, Single Pass Through | Tray | Active | AC/DC | Hall Effect, Open Loop | 100A | 1 | Ratiometric, Voltage (Selectable) | - | DC ~ 100kHz | ±0.5% | ±1% | 5V | 3.5µs | 25mA | -40°C ~ 105°C | - | - | Bidirectional | Through Hole | - |
|
CSHV200A-001CSHV200A-001 CURRENT SENSOR |
1,343 | - |
|
Datasheet | CSHV | Module, Single Pass Through | Box | Active | AC/DC | Hall Effect, Open Loop | 200A | 1 | Ratiometric, Voltage | 10mV/A | 45kHz | ±1% | ±2% | 4.5V ~ 5.5V | 6µs | 16mA | -40°C ~ 125°C | - | - | Bidirectional | Chassis Mount | - |
Current Sensors FAQs
Answers to common questions about component sourcing and electronic component sourcing.
Can HK CSY-ELECTRONICS help source Current Sensors components?
Submit part numbers, quantities and relevant requirements through our component RFQ form. Availability and quotation details are reviewed for each request.
Can I send a BOM for component sourcing?
Yes. Provide your bill of materials with required quantities and preferred manufacturers so our team can evaluate your sourcing request.
Do you also support PCB fabrication and assembly?
Yes. Our PCB and PCBA quotation form accepts board specifications and project files for fabrication and assembly inquiries.