PRODUCT CATEGORIES

Current Sensors

Explore Current Sensors components, specifications, manufacturers and sourcing options.

Browse Current Sensors parts and compare technical details, inventory references and datasheets to support your electronics project.

Submit part numbers or a BOM to request component pricing, availability and sourcing support.

Photo Mfr. Part # Availability Price Quantity Datasheet Series Package/Case Packaging Product Status For Measuring Sensor Type Current - Sensing Number of Channels Output Sensitivity Frequency Linearity Accuracy Voltage - Supply Response Time Current - Supply (Max) Operating Temperature Grade Qualification Polarization Mounting Type Supplier Device Package
LA 125-P/SP7 LEM USA Inc.

LA 125-P/SP7

SENSORS

LEM USA Inc.

2,615 -
Datasheet - - Bulk Active - - - - - - - - - - - - - - - - - -
LT 58-S7/SP8 LEM USA Inc.

LT 58-S7/SP8

TRANSDUCER

LEM USA Inc.

1,458 -
Datasheet LT Module, Single Pass Through Bulk Not For New Designs AC/DC Hall Effect, Closed Loop 50A 1 Current - DC ~ 100kHz ±0.2% ±0.8% ±12V ~ 15V 1µs - -25°C ~ 70°C - - Bidirectional Chassis Mount -
LA 306-S/SP1 LEM USA Inc.

LA 306-S/SP1

SENSORS

LEM USA Inc.

2,447 -
Datasheet LA Module, Single Pass Through Bulk Active AC/DC Hall Effect, Closed Loop 400A 1 Current - DC ~ 50kHz ±1% ±1.1% ±15V 1µs - -40°C ~ 85°C - - Bidirectional Chassis Mount -
LA 306-S/SP2 LEM USA Inc.

LA 306-S/SP2

SENSORS

LEM USA Inc.

2,862 -
Datasheet LA Module, Single Pass Through Bulk Active AC/DC Hall Effect, Closed Loop 300A 1 Current - DC ~ 50kHz ±1% ±1.1% ±24V 1µs - -40°C ~ 75°C - - Bidirectional Chassis Mount -
20320500101 HARTING

20320500101

CURRENT SENSOR HAN OPEN LOOP 500

HARTING

1,985 -
Datasheet - - Bulk Obsolete AC/DC Current Sensor 500A - - - DC ~ 50kHz - - - - - -25°C ~ 85°C - - - Chassis Mount -
LAX 100-NP/SP1 LEM USA Inc.

LAX 100-NP/SP1

Linear IC

LEM USA Inc.

1,967 -
Datasheet LAX Module Bulk Not For New Designs AC/DC Hall Effect, Closed Loop 100A 1 Current 0.5mA/A DC ~ 300kHz ±0.06% ±0.47% ±11.4V ~ 15.75V 12µs - -40°C ~ 85°C - - Bidirectional Through Hole -
CTSR 0.3-P/SP3 LEM USA Inc.

CTSR 0.3-P/SP3

TRANSDUCER

LEM USA Inc.

4,249 -
Datasheet CTSR Module, Single Pass Through Bulk Active AC/DC Flux Gate, Closed Loop 300mA 1 Voltage 4V/A DC ~ 3.5kHz ±0.5% ±1.9% 4.75V ~ 5.25V 50µs 21.6A -40°C ~ 105°C - - Unidirectional Through Hole -
CTSR 0.3-P/SP5 LEM USA Inc.

CTSR 0.3-P/SP5

TRANSDUCER

LEM USA Inc.

2,345 -
Datasheet CTSR Module, Single Pass Through Bulk Active AC/DC Flux Gate, Closed Loop 300mA 1 Voltage 4V/A DC ~ 3.5kHz ±0.5% ±1.9% 4.75V ~ 5.25V 50µs 21.6A -40°C ~ 105°C - - Unidirectional Through Hole -
CSCA0075A000U12J01 Honeywell Sensing and Productivity Solutions

CSCA0075A000U12J01

CURRENT SENSOR-OPEN LOOP

Honeywell Sensing and Productivity Solutions

1,979 -
Datasheet * - Bulk Active - - - - - - - - - - - - - - - - - -
351-1 Peltec Timers and Controls

351-1

CURRENT SENSOR: 0.1 TO 1 AMP

Peltec Timers and Controls

4,463 -
Datasheet 300 Module Box Active AC/DC Current Sensor 1A 3 Relay, SPDT - 50Hz/60Hz - ±5% 24V ~ 240V - - -20°C ~ 55°C - - - DIN Rail -
CTSR 3-TP/SP20 LEM USA Inc.

CTSR 3-TP/SP20

TRANSDUCER

LEM USA Inc.

1,861 -
Datasheet - - Bulk Active - - - - - - - - - - - - - - - - - -
LA 200-P/SP3 LEM USA Inc.

LA 200-P/SP3

SENSORS

LEM USA Inc.

2,370 -
Datasheet LA Module Bulk Active AC/DC Hall Effect, Closed Loop 200A 1 - - DC ~ 100kHz ±0.15% ±0.65% 12V ~ 15V 1µs 16mA -40°C ~ 85°C - - Bidirectional Chassis Mount -
351-5 Peltec Timers and Controls

351-5

CURRENT SENSOR: 0.5 TO 5 AMP

Peltec Timers and Controls

1,326 -
Datasheet 300 Module Box Active AC/DC Current Sensor 5A 3 Relay, SPDT - 50Hz/60Hz - ±5% 24V ~ 240V - - -20°C ~ 55°C - - - DIN Rail -
351-16 Peltec Timers and Controls

351-16

CURRENT SENSOR: 1.6 TO 16 AMP

Peltec Timers and Controls

4,546 -
Datasheet 300 Module Box Active AC/DC Current Sensor 16A 3 Relay, SPDT - 50Hz/60Hz - ±5% 24V ~ 240V - - -20°C ~ 55°C - - - DIN Rail -
351-8 Peltec Timers and Controls

351-8

CURRENT SENSOR: 0.8 TO 8 AMP

Peltec Timers and Controls

2,845 -
Datasheet 300 Module Box Active AC/DC Current Sensor 8A 3 Relay, SPDT - 50Hz/60Hz - ±5% 24V ~ 240V - - -20°C ~ 55°C - - - DIN Rail -
CSNV500M-156 Honeywell Sensing and Productivity Solutions

CSNV500M-156

CSNV500 SERIES HALL-BASED CLOSED

Honeywell Sensing and Productivity Solutions

1,267 -
Datasheet CSNV500 Module, Single Pass Through Box Active AC/DC Hall Effect, Closed Loop 500A 1 CAN Bus - - ±0.1% ±0.5% 7V ~ 18V - 250mA -40°C ~ 85°C - - Bidirectional Chassis Mount -
CSNV500M-126 Honeywell Sensing and Productivity Solutions

CSNV500M-126

CSNV500 SERIES HALL-BASED CLOSED

Honeywell Sensing and Productivity Solutions

2,223 -
Datasheet CSNV500 Module, Single Pass Through Box Active AC/DC Hall Effect, Closed Loop 500A 1 CAN Bus - - ±0.1% ±0.5% 7V ~ 18V - 250mA -40°C ~ 85°C - - Bidirectional Chassis Mount -
HAH3DR 900-S0D LEM USA Inc.

HAH3DR 900-S0D

TRANSDUCER

LEM USA Inc.

2,316 -
Datasheet HAH3DR Module Bulk Active AC/DC Hall Effect, Open Loop 900A 1 Ratiometric, Voltage 2.22mV/A DC ~ 40kHz ±1% ±3.75% 4.75V ~ 5.25V 6µs 60mA -40°C ~ 125°C - - Unidirectional Chassis Mount -
LAC 300-S/SP5 LEM USA Inc.

LAC 300-S/SP5

SENSORS

LEM USA Inc.

3,912 -
Datasheet LAC Module, Single Pass Through Bulk Active AC/DC Hall Effect, Closed Loop 200A 1 Current - DC ~ 50kHz ±0.1% ±1% ±24V 1µs - -40°C ~ 85°C - - Bidirectional Chassis Mount -
HAH1DR-200S LEM USA Inc.

HAH1DR-200S

SENSOR CURRENT HALL 200A AC/DC

LEM USA Inc.

3,610 -
Datasheet - Module, Single Pass Through Bulk Obsolete AC/DC Hall Effect, Open Loop 200A 1 Ratiometric, Voltage 10mV/A 30kHz ±1% - 4.75V ~ 5.25V 6µs 20mA -40°C ~ 125°C - - Bidirectional Chassis Mount -
Total 5184 Record«Prev1... 175176177178179180181182...260Next»
COMPONENT SOURCING SUPPORT

Need Help Finding Electronic Components?

Share your part numbers or BOM for electronic component sourcing, pricing, availability and lead-time support.

Electronic component RFQ service Component pricing & availability
FREQUENTLY ASKED QUESTIONS

Current Sensors FAQs

Answers to common questions about component sourcing and electronic component sourcing.

Can HK CSY-ELECTRONICS help source Current Sensors components?

Submit part numbers, quantities and relevant requirements through our component RFQ form. Availability and quotation details are reviewed for each request.

Can I send a BOM for component sourcing?

Yes. Provide your bill of materials with required quantities and preferred manufacturers so our team can evaluate your sourcing request.

Do you also support PCB fabrication and assembly?

Yes. Our PCB and PCBA quotation form accepts board specifications and project files for fabrication and assembly inquiries.