Circuit Breakers
Explore Circuit Breakers components, specifications, manufacturers and sourcing options.
Browse Circuit Breakers parts and compare technical details, inventory references and datasheets to support your electronics project.
Submit part numbers or a BOM to request component pricing, availability and sourcing support.
| Photo | Mfr. Part # | Availability | Price | Quantity | Datasheet | Series | Packaging | Product Status | Mounting Type | Breaker Type | Current Rating (Amps) | Voltage Rating - AC | Voltage Rating - DC | Actuator Type | Number of Poles | Illumination | Illumination Voltage (Nominal) | Approval Agency |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
GFL2B160302MCCB+EGFP 16A240V AC 30MA B TRIP |
2,639 | - |
|
Datasheet | GFL | Bulk | Discontinued at Digi-Key | DIN Rail | Ground Fault | 16A | 240 V | - | Lever | 1 | None | - | cULus, UL489 |
|
GFL2B200102MCCB+EGFP 20A240V AC 10MA B TRIP |
4,786 | - |
|
Datasheet | GFL | Bulk | Discontinued at Digi-Key | DIN Rail | Ground Fault | 20A | 240 V | - | Lever | 2 | None | - | cULus, UL489 |
|
GFL2B200302MCCB+EGFP 20A240V AC 30MA B TRIP |
6,013 | - |
|
Datasheet | GFL | Bulk | Discontinued at Digi-Key | DIN Rail | Ground Fault | 20A | 240 V | - | Lever | 1 | None | - | cULus, UL489 |
|
GFL2B20030SMCCB+EGFP 20A120240V AC 30MA B T |
5,707 | - |
|
Datasheet | GFL | Bulk | Discontinued at Digi-Key | DIN Rail | Ground Fault | 20A | 240 V | - | Lever | 2 | None | - | cULus, UL489 |
|
GFL2B250102MCCB+EGFP 25A240V AC 10MA B TRIP |
8,499 | - |
|
Datasheet | GFL | Bulk | Discontinued at Digi-Key | DIN Rail | Ground Fault | 25A | 240 V | - | Lever | 2 | None | - | cULus, UL489 |
|
GFL2B250302MCCB+EGFP 25A240V AC 30MA B TRIP |
7,376 | - |
|
Datasheet | GFL | Bulk | Discontinued at Digi-Key | DIN Rail | Ground Fault | 25A | 240 V | - | Lever | 1 | None | - | cULus, UL489 |
|
GFL2B30030SMCCB+EGFP 30A120240V AC 30MA B T |
9,380 | - |
|
Datasheet | GFL | Bulk | Discontinued at Digi-Key | DIN Rail | Ground Fault | 30A | 240 V | - | Lever | 2 | None | - | cULus, UL489 |
|
GFL2B30030SNMCCB+EGFP 30A120240V AC 30MA B T |
6,772 | - |
|
Datasheet | GFL | Bulk | Discontinued at Digi-Key | DIN Rail | Ground Fault | 30A | 240 V | - | Lever | 2 | None | - | cULus, UL489 |
|
GFL2B40030SMCCB+EGFP 40A120240V AC 30MA B T |
3,724 | - |
|
Datasheet | GFL | Bulk | Discontinued at Digi-Key | DIN Rail | Ground Fault | 40A | 240 V | - | Lever | 2 | None | - | cULus, UL489 |
|
GFL2C05010SMCCB+EGFP 5A120240V AC 10MA C TR |
4,301 | - |
|
Datasheet | GFL | Bulk | Discontinued at Digi-Key | DIN Rail | Ground Fault | 5A | 240 V | - | Lever | 2 | None | - | cULus, UL489 |
|
GFL2C050302MCCB+EGFP 5A240V AC 30MA C TRIP |
8,335 | - |
|
Datasheet | GFL | Bulk | Discontinued at Digi-Key | DIN Rail | Ground Fault | 5A | 240 V | - | Lever | 2 | None | - | cULus, UL489 |
|
GFL2C05030SMCCB+EGFP 5A120240V AC 30MA C TR |
2,773 | - |
|
Datasheet | GFL | Bulk | Discontinued at Digi-Key | DIN Rail | Ground Fault | 5A | 240 V | - | Lever | 2 | None | - | cULus, UL489 |
|
GFL2C051002MCCB+EGFP 5A240V AC 100MA C TRIP |
2,859 | - |
|
Datasheet | GFL | Bulk | Discontinued at Digi-Key | DIN Rail | Ground Fault | 5A | 240 V | - | Lever | 1 | None | - | cULus, UL489 |
|
GFL2C060302MCCB+EGFP 6A240V AC 30MA C TRIP |
3,978 | - |
|
Datasheet | GFL | Bulk | Discontinued at Digi-Key | DIN Rail | Ground Fault | 6A | 240 V | - | Lever | 2 | None | - | cULus, UL489 |
|
GFL2C06030SMCCB+EGFP 6A120240V AC 30MA C TR |
9,313 | - |
|
Datasheet | GFL | Bulk | Discontinued at Digi-Key | DIN Rail | Ground Fault | 6A | 240 V | - | Lever | 2 | None | - | cULus, UL489 |
|
GFL2C080302MCCB+EGFP 8A240V AC 30MA C TRIP |
8,631 | - |
|
Datasheet | GFL | Bulk | Discontinued at Digi-Key | DIN Rail | Ground Fault | 8A | 240 V | - | Lever | 2 | None | - | cULus, UL489 |
|
GFL2C100102MCCB+EGFP 10A240V AC 10MA C TRIP |
5,216 | - |
|
Datasheet | GFL | Bulk | Discontinued at Digi-Key | DIN Rail | Ground Fault | 10A | 240 V | - | Lever | 1 | None | - | cULus, UL489 |
|
GFL2C100302MCCB+EGFP 10A240V AC 30MA C TRIP |
6,189 | - |
|
Datasheet | GFL | Bulk | Discontinued at Digi-Key | DIN Rail | Ground Fault | 10A | 240 V | - | Lever | 1 | None | - | cULus, UL489 |
|
GFL2C10030SMCCB+EGFP 10A120240V AC 30MA C T |
5,298 | - |
|
Datasheet | GFL | Bulk | Discontinued at Digi-Key | DIN Rail | Ground Fault | 10A | 240 V | - | Lever | 2 | None | - | cULus, UL489 |
|
GFL2C101002MCCB+EGFP 10A240V AC 100MA C TRI |
5,922 | - |
|
Datasheet | GFL | Bulk | Discontinued at Digi-Key | DIN Rail | Ground Fault | 10A | 240 V | - | Lever | 1 | None | - | cULus, UL489 |
Circuit Breakers FAQs
Answers to common questions about component sourcing and electronic component sourcing.
Can HK CSY-ELECTRONICS help source Circuit Breakers components?
Submit part numbers, quantities and relevant requirements through our component RFQ form. Availability and quotation details are reviewed for each request.
Can I send a BOM for component sourcing?
Yes. Provide your bill of materials with required quantities and preferred manufacturers so our team can evaluate your sourcing request.
Do you also support PCB fabrication and assembly?
Yes. Our PCB and PCBA quotation form accepts board specifications and project files for fabrication and assembly inquiries.