| Photo | Mfr. Part # | Availability | Price | Quantity | Datasheet | Series | Packaging | Product Status | Mounting Type | Breaker Type | Current Rating (Amps) | Voltage Rating - AC | Voltage Rating - DC | Actuator Type | Number of Poles | Illumination | Illumination Voltage (Nominal) | Approval Agency |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|
3120-N324-P7T1-W19DG4-5ACIR BRKR THRM SWITCH 5A IP65 |
3,770 | - |
|
Datasheet | 3120-N | Box | Active | Panel Mount | Thermal | 5A | 415 V | 50 V | Rocker | 2 | Green | 230V | CSA C22.2 No 235, GB 17701, IEC 60934, UL1077 |
|
3-150-707TA35 CIRCUIT BREAKER 2P 16A F2 |
2,241 | - |
|
Datasheet | TA35 | Box | Active | Panel Mount | Thermal Magnetic | 16A | 240 V | 32 V | Rocker | 2 | Green | - | CSA C22.2 No 235, GB 17701, IEC 60934, IEC 62368-1, UL1077 |
|
3-150-708TA35 CIRCUIT BREAKER 2P 16A T2 |
3,451 | - |
|
Datasheet | TA35 | Box | Active | Panel Mount | Thermal Magnetic | 16A | 240 V | 32 V | Rocker | 2 | Green | - | CSA C22.2 No 235, GB 17701, IEC 60934, IEC 62368-1, UL1077 |
|
IPA-6-1REG4-52-.500-01CIR BRKR MAG-HYDR LEVER .5A |
1,121 | - |
|
Datasheet | IPA | Bulk | Active | Panel Mount | Magnetic (Hydraulic Delay) | 500mA | - | - | Lever | 1 | - | - | - |
|
|
IELK1-1-62-20.0-01-VCIR BRKR MAG-HYDR LEVER 20A |
2,885 | - |
|
Datasheet | IEL | Bulk | Active | Panel Mount | Magnetic (Hydraulic Delay) | 20A | 250 V | - | Lever | 1 | None | - | UL1077 |
|
IELK1-1-72-25.0-01-VCIR BRKR MAG-HYDR LEVER 25A |
1,359 | - |
|
Datasheet | IEL | Bulk | Active | Panel Mount | Magnetic (Hydraulic Delay) | 25A | 250 V | 80 V | Lever | 1 | None | - | UL1077 |
|
IELK1-1-52-5.00-01-VCIR BRKR MAG-HYDR |
1,845 | - |
|
Datasheet | IEL | Bulk | Active | Panel Mount | Magnetic (Hydraulic Delay) | 5A | 415 V | 80 V | Lever | 1 | None | - | - |
|
IELK1-1-62-5.00-01-VCIR BRKR MAG-HYDR |
3,796 | - |
|
Datasheet | IEL | Bulk | Active | Panel Mount | Magnetic (Hydraulic Delay) | 5A | 415 V | 80 V | Lever | 1 | None | - | - |
|
IELK1-1-52-50.0-01-VCIR BRKR MAG-HYDR LEVER 50A |
3,299 | - |
|
Datasheet | IEL | Bulk | Active | Panel Mount | Magnetic (Hydraulic Delay) | 50A | - | - | Lever | 1 | - | - | - |
|
IELK1-1-62-20.0-91-VCIR BRKR MAG-HYDR LEVER 20A |
4,133 | - |
|
Datasheet | IEL | Bulk | Active | Panel Mount | Magnetic (Hydraulic Delay) | 20A | 250 V | - | Lever | 1 | None | - | UL1077 |
|
IULK1-1-62-20.0-01CIR BRKR MAG-HYDR 20A LEVER |
1,767 | - |
|
Datasheet | IUL | Bulk | Active | Panel Mount | Magnetic (Hydraulic Delay) | 20A | - | - | Lever | 1 | - | - | - |
|
IULK1-1-66-15.0-01CIR BRKR MAG-HYDR |
3,436 | - |
|
Datasheet | IUL | Bulk | Active | Panel Mount | Magnetic (Hydraulic Delay) | 10A | 250 V | 80 V | Lever | 1 | None | - | - |
|
IULK1-1-72-30.0-01CIR BRKR MAG-HYDR |
2,878 | - |
|
Datasheet | IUL | Bulk | Active | Panel Mount | Magnetic (Hydraulic Delay) | 7.5A | 250 V | 80 V | Lever | 1 | None | - | - |
|
IULK1-1-72-20.0-01CIR BRKR MAG-HYDR 20A LEVER |
1,769 | - |
|
Datasheet | IUL | Bulk | Active | Panel Mount | Magnetic (Hydraulic Delay) | 20A | - | - | Lever | 1 | - | - | - |
|
2800924CIR BRKR SOLID STATE 3A 24VDC |
1,097 | - |
|
Datasheet | CB | Bulk | Active | Holder | Solid State | 3A | - | 24 V | - | 1 | - | - | - |
|
2800908CIR BRKR SOLID STATE 1A 24VDC |
1,146 | - |
|
Datasheet | CB | Bulk | Active | Holder | Solid State | 1A | - | 24 V | - | 1 | - | - | - |
|
2800927CIR BRKR SOLID STATE |
4,136 | - |
|
Datasheet | - | Bulk | Active | Holder | Solid State | 8A | - | 24 V | Slide Switch | 1 | - | - | - |
|
2800906CB E1 24DC/8A NO P |
2,373 | - |
|
Datasheet | - | Bulk | Active | Panel Mount | Thermal Magnetic | 8A | - | 24 V | Push to Reset | 1 | - | - | - |
|
5SY41036CIRCUIT BREAKER 10KA 1POLE B3 |
1,340 | - |
|
Datasheet | 5SY4 | Bulk | Active | DIN Rail | - | - | 400 V | 72 V | Lever | 1 | None | - | CCC, EAC, IMQ, UR, VDE |
|
4430.2781CIR BRKR THRM 240VAC 60VDC |
2,541 | - |
|
Datasheet | TA45 | Bulk | Active | Panel Mount | Thermal | - | 240 V | 60 V | Rocker | 2 | - | - | CSA C22.2 No 235, EN 60934, GB 17701, IEC 60934, UL1077 |
Circuit Breakers FAQs
Answers to common questions about component sourcing and electronic component sourcing.
Can HK CSY-ELECTRONICS help source Circuit Breakers components?
Submit part numbers, quantities and relevant requirements through our component RFQ form. Availability and quotation details are reviewed for each request.
Can I send a BOM for component sourcing?
Yes. Provide your bill of materials with required quantities and preferred manufacturers so our team can evaluate your sourcing request.
Do you also support PCB fabrication and assembly?
Yes. Our PCB and PCBA quotation form accepts board specifications and project files for fabrication and assembly inquiries.